Installation manual: Preparation
4
EN
1. Installing the appliance
1.1 Technical information
Please refer to the technical information at the end of the manual (pages I to IV) for information relating
to:
• Package contents
• Technical specications.
1.2 Specic instructions for installation in a bathroom
• Installation outside areas V0, V1 and V2 (NF C 15-100).
If the bathroom dimensions do not allow the water heater to be positioned outside volumes V0, V1 and
V2:
It is then possible in area V2 or possible in area V1, if:
- the water heater is horizontal and positioned as high
up as possible (40, 65,80 and 100 L only)
- the pipes are made from a conductive material
- the water heater is protected by a circuit breaker with
a residual dierential current (30 mA) connected
upstream of the water heater