Questions and Answers

  • R
    Rodney SchaeferAug 19, 2025
    What to do if my THERMOBILE Heater stops burning and the reset button is lit?
    • J
      Julie SimpsonAug 20, 2025
      If your THERMOBILE Heater stops burning and the reset button is lit, it could be due to: * An air leak in the suction line or main filter: Check and replace if necessary. * A dirty or blocked protection grill for the air intake: Clean the grill. * A clogged heat exchanger: Clean the heat exchanger.
  • R
    randy94Aug 25, 2025
    Why does my THERMOBILE Heater stop completely?
    • N
      Nathan MackAug 26, 2025
      Your THERMOBILE Heater might stop completely due to: * An overheating problem inside the heater: Reset the thermostat. * High resistance at the outlet: Reduce the resistance at the outlet. If the problem persists, contact the dealer.
  • L
    Laura DoyleAug 28, 2025
    Why is my THERMOBILE Heater producing white smoke?
    • D
      Deborah WhiteAug 28, 2025
      If your THERMOBILE Heater is producing white smoke, it could be due to air in the fuel system. Check the fuel-supply system for leakage.
  • J
    jeffrey69Aug 31, 2025
    Why does my THERMOBILE Heater burn at short intervals?
    • W
      williambakerAug 31, 2025
      If your THERMOBILE Heater burns at short intervals, it might be because the burner thermostat has an incorrect adjustment. Adjust the burner thermostat according to the manufacturer's specifications.
  • B
    Billy HoldenSep 2, 2025
    Why does my THERMOBILE Heater use too much fuel?
    • R
      Rachel HallSep 2, 2025
      If your THERMOBILE Heater uses too much fuel: * The nozzle might be too big or the wrong type is used: Check the fuel pipes. * Replace the nozzle with the correct one.
  • K
    Kristen PetersSep 5, 2025
    Why does the burner start badly (pulsation) in my THERMOBILE Heater?
    • S
      steve73Sep 5, 2025
      If the burner starts badly (pulsation) in your THERMOBILE Heater, it could be due to: * Insufficient fresh air supply: Open a door or a window. Use an outside air suction device for the burner. * Problems with the burner chamber or the heat exchanger: Clean, repair or replace the burner chamber and heat exchanger, if necessary.
  • M
    Michael WilsonSep 8, 2025
    Why does the burner produce soot in my THERMOBILE Heater?
    • G
      Gina PhamSep 8, 2025
      If the burner produces soot in your THERMOBILE Heater, the air inlet may not be set correctly. Adjust the air inlet.
  • W
    Wendy BerrySep 12, 2025
    What to do if my THERMOBILE Heater cannot be switched off?
    • C
      Catherine RiosSep 12, 2025
      If your THERMOBILE Heater cannot be switched off, it may be because the magnet valve does not close. Close the valve of the fuel supply.
  • F
    fmeyersSep 13, 2025
    What to do if the burner starts, the flame is built, but the burner stops in my THERMOBILE Heater?
    • G
      Gregory RojasSep 13, 2025
      If the burner starts, the flame is built, but the burner stops in your THERMOBILE Heater, it could be that the burner relay has a failure. Repair or replace the burner relay.
  • D
    Dawn CunninghamNov 16, 2025
    What to do if my THERMOBILE Heater does not start up?
    • T
      Tonya JohnsonNov 16, 2025
      If your THERMOBILE Heater doesn't start, there could be several reasons: * There's no electric power: Check the power connection. * The burner relay is in failure: Push the reset button of the burner relay. * A malfunction has occurred in the burner relay: Replace the burner relay. * The thermostat settings are incorrect: Correct the settings. * The room thermostat is defective: Replace the thermostat. * No cap is present on the thermostat connection: Place the cap if a room thermostat is not used. * The fuel pump is blocked: Replace the fuel pump. * The maximum thermostat stopped the heater: Check (and correct) the airflow and reset the heater. * The digital combination thermostat or sensor is defective: Replace the digital combination thermostat or sensor. * The main...

THERMOBILE IMA US Series Specifications

General IconGeneral
Fuel TypeDiesel
Heating CapacityVaries by model
AirflowVaries by model
Safety FeaturesOverheat protection, flame sensor
DimensionsVaries by model
WeightVaries by model