Model No.: TP-67
V201808 EN FR31
Wireless Weather Station
Instruction Manual
English................. 2 Fraais............... 14
Question and Answer IconNeed help?

Do you have a question about the ThermoPro TP-67 and is the answer not in the manual?

ThermoPro TP-67 Specifications

General IconGeneral
Temperature Range (Indoor)32°F to 122°F (0°C to 50°C)
Humidity Range10% to 99%
DisplayLCD
Refresh Rate60 seconds
Wireless Range200 feet (60 meters)
Power Source (Main Unit)2 x AAA batteries
Power Source (Receiver)2 x AAA batteries (not included)
Power Source (Remote Sensor)2 x AAA batteries (not included)

Summary

Introduction to the Weather Station

Device Components Overview

Product Features and Specifications

LCD Display Functionality

Displays current temperature, humidity, barometric pressure, and weather forecast.

Indoor Temperature and Humidity Range

Specifies the operating range for indoor temperature (-20°C to 70°C) and humidity (10% to 99%).

Outdoor Temperature Range

Specifies the operating range for outdoor temperature (-50°C to 70°C).

Temperature and Humidity Tolerance

Defines the accuracy tolerance for temperature (+/- 1.1°C) and humidity (+/- 2-3%).

Low Battery Indicator

Alerts the user when the base station or remote sensor battery is low.

Backlit Display Feature

The LCD display includes a backlight for improved visibility.

Mounting Design Options

Features a tabletop and wall-mountable design with a detachable base.

Remote Sensor Rain Protection

The remote sensor is designed to be rain-proof for outdoor use.

Power Source Requirements

Details battery requirements: 2*AAA for base, 18650 lithium for remote.

Base Station Receiver Components

Large LCD Display

The primary display screen showing all weather data and icons.

Weather Forecast Indicator

Displays predicted weather conditions using graphical symbols.

Outdoor Temperature Display

Shows the current temperature measured by the remote sensor.

Base Station Low Battery Icon

Indicates a low battery level for the base station unit.

Indoor Temperature Display

Shows the current temperature inside the base station's location.

Backlight Control Button

Button to activate or deactivate the display backlight.

Remote Sensor Low Battery Icon

Indicates a low battery level for the outdoor remote sensor.

Indoor Humidity Display

Shows the current humidity level inside the base station's location.

Barometric Pressure Display

Displays the current atmospheric pressure reading.

Pressure Unit Selection (inHg/mb)

Button to switch barometric pressure units between inHg and mb (hPa).

Temperature Unit Selection (°C/°F)

Button to switch temperature units between Celsius (°C) and Fahrenheit (°F).

Weather Forecast Button

Button to select the weather symbol for forecast display.

Wall Hanging Hole

Provision for mounting the base station on a wall.

Battery Compartment Access

Location for accessing and replacing batteries.

History Data Button

Press to view the past 12 hours of barometric pressure data.

Max/Min Data Button

Press to view maximum and minimum recorded temperature/humidity.

Channel Selection Button

Press to cycle through registered outdoor sensors.

Base Station Button Operations

LIGHT Button Operation

Press to turn the display backlight on or off.

WEATHER Button Function

Select one of five weather conditions to reflect current weather.

°C/°F Button Function

Press to select the desired temperature display unit (°C or °F).

inHg/mb Button Function

Press to select barometric pressure display unit (inHg or mb).

Base Station Button Operations Continued

HISTORY Button Operation

Press to display barometric pressure records for the past 12 hours.

MAX/MIN Button Operation

Display max/min temp/humidity; press and hold to clear records.

CHANNEL Button Operation

Display readings from up to 3 sensors; hold to enter sync mode.

Temperature and Humidity Trend Indicators

Outdoor Remote Sensor Details

Sensor Wall Hanging Hole

A feature for mounting the remote sensor on a wall.

Sensor Reset Button

Button to reset the remote sensor to its default settings.

Sensor LED Indicator

An LED light on the sensor indicating status like charging or power.

External Temperature Sensor

The integrated sensor that measures outdoor temperature.

Sensor Charging Socket

The port used to recharge the remote sensor's internal battery.

Sensor Power ON/OFF Switch

Switch to turn the remote sensor unit on or off.

Sensor Channel Selector

Slider to set the sensor to channel 1, 2, or 3.

Sensor Channel Selection

Set the sensor to a specific channel (1, 2, or 3) for communication.

Sensor Reset Procedure

Instructions on how to press the reset button for the sensor.

Sensor Power ON/OFF Procedure

How to turn the remote sensor on/off by holding the ON/OFF button.

Remote Sensor Charging Guide

Low Battery Warning Indicators

Display Unit Selection Options

Synchronizing Remote Sensors with Base Station

Initial Sensor Placement

Place the remote sensor near the base station to initiate pairing.

Initiating Base Station Sync Mode

Insert batteries into base station; RF indicator flashes for 3 mins.

Setting Remote Sensor Channel

Set the channel selector on the remote sensor (1, 2, or 3).

Activating Remote Sensor

Press and hold the ON/OFF button on the sensor for 2 seconds.

Troubleshooting Synchronization Failures

Re-press and hold CHANNEL button if sync fails after 3 minutes.

Synchronizing Multiple Sensors

Repeat steps to register additional sensors, ensuring different channels.

Selecting Displayed Sensor Channel

Press CHANNEL on base station to select a sensor or auto-scroll.

Temperature Measurement Functions

Displaying Synchronized Readings

Shows indoor/outdoor temperature and humidity after synchronization.

Viewing Maximum and Minimum Records

Display highest (MAX) and lowest (MIN) recorded temp/humidity.

Understanding Temperature/Humidity Trends

Interprets icons indicating increasing, steady, or decreasing trends.

Barometric Pressure Functions

Viewing Barometric Pressure History

Press HISTORY to show barometric pressure for the past 1 to 12 hours.

Interpreting Barometric Pressure Trend Graph

The display graph shows barometric pressure changes over the last 12 hours.

Weather Forecast Functionality

Setting Initial Weather Condition

Set current weather condition for accurate future forecasts.

Using the WEATHER Button

Press the WEATHER button to change displayed weather symbols.

Interpreting Weather Forecast Symbols

Placement Guidelines for Units

Base Station Placement Recommendations

Place base station in a well-ventilated indoor area away from direct heat/sun.

Remote Sensor Placement Recommendations

Place sensor on flat surface, indoors or outdoors, protected from direct rain.

Wall Mounting Both Units

Both the base station and remote sensor can be mounted on walls.

Purchasing Additional Sensors

Connection Troubleshooting Tips

Receiver Not Connecting to Transmitter

Try re-syncing or relocating the units if connection is lost.

Product Warnings and Precautions

Avoid Excessive Force and Shock

Do not subject the unit to excessive force, shock, dust, temperature, or humidity.

Keep Unit Away from Water

Do not immerse the unit in water or expose to excessive moisture.

Do Not Disassemble Unit

Do not attempt to remove any screws or take the unit apart.

Fire Hazard Warning

Do not dispose of the unit in a fire, as it may explode.

Choking Hazard Warning

Keep the unit and its parts away from children due to choking hazard.

Legal and Responsible Disposal

Dispose of the unit legally and recycle when possible.

Detailed Technical Specifications

Transmission Frequency

Operates on a 433 MHz transmission frequency.

Maximum Transmit Power

The maximum transmit power is 8 mW.

Transmission Range

Up to 200 feet in open area; range may be shorter with interference.

Indoor Temperature Operating Range

Range: -4°F to 158°F (-20°C to 70°C).

Outdoor Temperature Operating Range

Range: -58°F to 158°F (-50°C to 70°C).

Humidity Operating Range

Range: 10% to 99%.

Temperature Measurement Tolerance

Tolerance: +/- 2.0°F (+/- 1.1°C).

Humidity Measurement Tolerance

Tolerance: ±2% (30-80%), ±3% (below 30% & above 80%).

Power Source Details

Base: 2*AAA 1.5V; Remote: 18650 lithium 3.7V.

Battery Disposal Guidelines

Equipment Disposal Guidelines

FCC Statement of Compliance

Adherence to FCC Part 15 Rules

Device complies with FCC Part 15, subject to two conditions.

Warning Against Unit Modifications

Unauthorized modifications can void user's authority to operate.

Class B Digital Device Compliance Note

Tested and compliant with Class B digital device limits for interference.

Declaration of Conformity

Limited One-Year Warranty

Customer Service Information