4
General Warnings
Caution: above 50 °C, water could cause immediate burns. Check the water
temperature before taking a bath or shower.
HYDRAULIC CONNECTION
y A new safety device (or any other new pressure relief valve), with a pressure
of either 0.7 or 0.9 MPa (7 or 9 bar), depending on the nominal pressure,
and measuring 3/4’’ in diameter, must be tted on the water heater inlet, in
accordance with the local standards in force (see the diagram on page B).
y No hydraulic accessories must be installed between the safety device and
the cold water inlet of the appliance. A pressure reducer (not supplied) is
required if the supply pressure is greater than 0.5 MPa (5 bar) and will be
installed on the main supply pipe.
y Connect the safety device to a discharge pipe, kept in the open air, in
a frost-free environment, continuously sloping downwards to drain o󰀨 the
heat-expanded water or to allow for drainage of the water heater.
y The pressure relief valve drainage device must be activated on a regular
basis in order to remove limescale deposits and to check that it is not
blocked.
y To drain the appliance, turn o󰀨 the power and cold water supply, open the
hot water taps then operate the drainage valve of the safety device.
y The pipes used must be able to withstand 1 MPa (10 bar) and 100 °C.
ELECTRICAL CONNECTION
y Be sure to turn o󰀨 the power before removing the cover, to prevent any risk
of injury or electric shock.
y Upstream of the appliance, the electrical installation must have an all-pole
cut-out device (circuit breaker, fuse) compliant with the local installation
rules in force (30 mA residual current device).
y If the cable is damaged, it must be replaced with a cable or a special pack
available from the manufacturer or the After-Sales service.
y Earthing is mandatory. A special terminal marked is provided for this
purpose.
y Products including a battery: There is a risk of explosion if the battery is
replaced with an incorrect battery. Dispose of used batteries in accordance
with local regulations.
y The user manual for this appliance can be obtained from the After-Sales
service.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermor DURALIS CONNECT 150 and is the answer not in the manual?

Thermor DURALIS CONNECT 150 Specifications

General IconGeneral
BrandThermor
ModelDURALIS CONNECT 150
CategoryWater Heater
LanguageEnglish

Related product manuals