Loading...
MT8206
PRELIMINARY, SUBJECT TO CHANGE WITHOUT NOTICE MTK CONFIDENTIAL, NO DISCLOSURE
June, 2006
Table 2-2.
Variable Nominal (mil) Tolerance Min. (mil) Max. (mil)
Trace High (H)
4.5 (2116)
Trace Width (W)
5 + / - 1 mil 4 6
Spacing (S)
8 (mil) + / - 1 mil 9 7
Spacing to GND(Sg)
8 (mil) + / - 1 mil 9 7
Single Ended Trace
Impedance
55 60 50.5
Differential Trace
Impedance
97 107 87
Reference Plane
Ground Ground Ground Ground
Note:
¾ Keeping the spacing to the other signals as far as possible.
¾ Keeping the spacing to different ground planes (Sp) more than 30 mils as possible as the Fig. 2-3.
Fig. 2-3 Cross-Section of Plane Designated