6.The appliance must be isolated from the building’s gas supply piping system by closing its individual
manual shut-off valve during any pressure testing of the gas supply piping system at test pressure equal
to or less than
1
/
2
psig(3.5kPa).
After installation:
Check ignition of cooktop burners.
Check ignition of oven burner.
Visually check tubular burner (oven burner) re-ignition to be sure both rows of burner ports are
relighting each time.
Check for gas leaks at all gas connections (using a gas detector, never a flame).
Check oven bake and convection bake function.