9
TROUBLESHOOTING GUIDE
Troubleshooting Guide
Please note:
Solar panels and controller are maintenance free.
There are no user service parts in this unit.
If you have any problems, please contact Thunder. See back of booklet for
details.
The charge LED doesn’t glow green
Ensure the panels are exposed to sunlight.
Ensure all panel cables are free from damage and are connected correctly.
Ensure the cables from the controller to the battery are free from damage
and connected correctly.
Check the battery voltage. If the battery voltage is less than 8V, the
controller will not work.
Check the fuse. The fuse will typically be blown for the following reasons:
- Battery poles +/- are reversed or a short circuit occurred.
- Solar controller output current over 10A.
Inspect and test the battery. Check if the battery is in good condition.
There is no voltage output from the panel
Check if the output cables are connected to the battery correctly.
The panel is fitted with a SMART controller that will not allow any output if
the panel is not connected. This protects the solar panel.