2007.03.07Flow2 stairliftTab 06: Systematic fault finding
www.ThyssenKruppAccessibility.nl26
Error messages
Error code E50
Type of error System error / user error
Error message Low battery
Description Indicates that the batteries are empty.
Priority High
Possible
solution
- Position the lift at the charging contact.
- Check that the charger is working.
- Check the battery fuses (40 A)
- Check the battery wiring.
Reset Switch off and on.
Modes 0, 1, 2, 3, 4, 5, 6
Error code E51
Type of error System error
Error message Osg tripped
Description This message indicates that the overspeed governer has been activated.
Priority Average
Possible
solution
See Error code E51
Reset Switch off and on.
Modes 0, 2
Error code E52
Type of error System error / control error
Error message Levelling ouside limits
Description The chair is tilted because of a levelling error.
Priority Average