WAVEJET MICROWAVE OVEN
© Copyright 2003
25-30-43
Page TP1
March 15, 2003
COMPONENT MAINTENANCE MANUAL
WITH ILLUSTRATED PARTS LIST
WAVEJET
®
MICROWAVE OVEN
28 VOLTS DC
Part Number 400-1338-02
Part Number 400-1409-02
Part Number 400-1746-02
Part Number 400-1860-01
a division of The Richards Corporation
DESIGNERS AND MANUFACTURERS OF AIRCRAFT GALLEY INSERT EQUIPMENT
44931 FALCON PLACE l STERLING VA 20166
WWW.TIAPRODUCTS.COM l TIA@TIAPRODUCTS.COM
(703) 471-8600 l FAX (703) 481-5007

Questions and Answers

  • M
    Matthew JohnsonAug 13, 2025
    What to do if the TIA Microwave Oven display is active, +/- respond, counts down when “Start” is pressed, turntable turns, but microwave does not heat?
    • J
      Jeanette WilliamsAug 13, 2025
      If the turntable turns but the microwave doesn't heat, check for relay failure. If that's not the issue, check for noise filter failure. If the problem persists, check for power supply or magnetron failure.
  • K
    kzimmermanAug 16, 2025
    Why is the display not illuminated on my TIA Microwave Oven?
    • J
      Jason WhiteAug 16, 2025
      If the display numbers are not illuminated, it could be due to several reasons: * No or low input voltage: Measure the input voltage; it should be 28 Volts DC. Check the load shed circuit on the aircraft. * Check the load shed circuit on the aircraft and load shed fuse in the microwave. * Check the load shed fuse in the microwave (P/N 400-1860-01 only) and noise filter. * Noise filter failure: Check the controller card for failure. * Controller card failure: Check the liner overheat thermostat. * Check the liner overheat thermostat.
  • B
    Brandon FrancisAug 20, 2025
    What to do if the TIA Microwave Oven display is active, controls are unresponsive?
    • J
      james09Aug 20, 2025
      If the display is active but the controls are unresponsive, check the switch panel overlay for failure. If the issue continues, check the controller card for failure.
  • A
    alexa35Aug 25, 2025
    What to do if the TIA Microwave Oven display is active, +/- respond, counts down when “Start” is pressed, turntable does not turn and microwave heats?
    • R
      romeromarkAug 25, 2025
      If the turntable does not turn but the microwave heats, check for inverter board failure and then check for turntable motor failure.
  • P
    Pamela AshleyAug 28, 2025
    What to do if liner or magnetron thermostat opens frequently in TIA Microwave Oven?
    • T
      Tiffany AdamsAug 28, 2025
      If the liner or magnetron thermostat opens frequently, check that the microwave installation allows for adequate fan ventilation. Also, check for power output.
  • J
    Jennifer SavageAug 31, 2025
    How to fix TIA Microwave Oven when display is active, +/- respond, but will not count down when “Start” is pressed and inside lamps stay on?
    • L
      Lisa JohnsonSep 1, 2025
      If the display is active, the +/- buttons respond, but the microwave will not count down when “Start” is pressed and the inside lamps stay on, check all door interlock switches. One or more may be stuck open or need adjustment.
  • T
    Tyler SantiagoSep 4, 2025
    What to do if TIA Microwave Oven display is active, +/- respond, counts down when “Start” is pressed, turntable does not turn and microwave does not heat?
    • J
      Johnny EvansSep 4, 2025
      If the display is active, the +/- buttons respond, the microwave counts down when “Start” is pressed, but the turntable does not turn and the microwave does not heat, check the magnetron thermostat to see if it is open. Verify the cabin altitude is less than 9,000 feet. Check the altitude switch and check for controller card failure.
  • J
    Jeffrey BrownSep 8, 2025
    Why don't the lamps light in my TIA Microwave Oven when display is active, +/- respond, counts down when “Start” is pressed, turntable turns and microwave heats?
    • C
      clarkjamesSep 8, 2025
      If the display is active, the +/- buttons respond, the microwave counts down when “Start” is pressed, the turntable turns and the microwave heats, but the lamps do not light, the lamps have burned out and need to be replaced. TIA recommends that the lights be replaced in sets.

Summary

Leading Particulars and Specifications

Description and Operation

General Description and Features

Overview of the oven's features, reliability, and load shed circuit functionality.

Operation and Storage

Operating the Microwave

Instructions for using the microwave, including setting time and cooking.

Testing and Troubleshooting

Testing Procedures

Outlines equipment needed and steps for functional testing of the oven.

Troubleshooting Guide and Fault Isolation

Lists common faults, probable causes, and fault isolation tables.

Disassembly Procedures

Cleaning and Inspection

Inspection and Functional Checks

Details visual inspection points and functional checks for proper operation.

Repair and Assembly Procedures

Repair and Replacement

Covers general repair, lamp, wiring, and turntable component replacement.

Special Tools and Parts Lists

TIA WAVEJET 400-1860-01 Specifications

General IconGeneral
BrandTIA
ModelWAVEJET 400-1860-01
CategoryMicrowave Oven
LanguageEnglish

Related product manuals