Disassembly
of
movement
for
Cleaning
(model
80)
DIAL
PLATE
MOVEMENT
PLATE
a)
Remove
the sweep second hand,
do
not remove the minute
or
hour hand.
b)
The
dial
is
clamped
to
the
movement
by
means
of
tabs
which are inserted through
dial
holes located
in
the
dial
spacer
and
dial
plate.
The
tabs are
bent under the
dial
plate.
c)
Once the dial
is
off
the move-
ment, there
is
no need
for
furth-
er disassembly
in
the
dial
area
unless severe contamination
is
present on the friction and can-
non pinions. Should
further
disassembly be necessary, re-
moval
of
the minute hand
will
free the friction and cannon
pinion assembly.
The
friction
pinion
is
held in the cannon
pinion
by
a snap fit.
80.3