Explains the PID control system for precise spatial temperature variations up to 450°C.
Explains the PPDT's requirement for Procedure B and its function in measuring piston position.
Provides instructions for safely unpacking the machine from its crate and checking components.
Advises on selecting a suitable location for the machine, ensuring a stable and vibration-free environment.
Details the process of leveling the machine using adjustment feet for accurate operation.
Provides instructions and tools required for installing the PPDT when ordered with the MP1200.
Guides the user through the DC motor calibration process for the WLD.
Provides step-by-step instructions for synchronizing the WLD encoder with the PPDT.
Details the manual and software-guided operation of the pneumatic purge and cleaning features.
Guides users on configuring machine settings like name, max temperature, and accessory activation (PPDT, WLD, Purge, Clean, Cut).
Explains the Proportional, Integral, Derivative (PID) temperature control parameters and tuning.
Details the calibration procedures for RTD, PPDT, and WLD, accessed via the Configuration mode.
Explains how to enter calibration offsets to correct temperature differences for accurate readings.
Details the process of creating and configuring a new test program for ASTM D 1238 Procedure A.
Guides users through creating a new test program for ASTM D 1238 Procedure B with known melt density.
Details the step-by-step procedure for performing melt index tests using Procedure B with known melt density.
Guides users in creating a test program for Procedure B to calculate melt density when it's unknown.
Outlines the step-by-step procedure for performing melt index tests to calculate melt density.
Provides essential instructions for thoroughly cleaning the cylinder, die, and piston after each test.
Emphasizes the importance of cleanliness for maintaining melt index machine accuracy.
Outlines the procedure for calibrating and verifying the PPDT measuring capabilities using the PPDT Calibrator.
Explains the process for verifying and calibrating the machine's temperature readings using suggested equipment.
Provides an overview of PID temperature control concepts and tuning for optimal performance.
Explains the PID temperature control interface showing P, I, and D terms for each of the three temperature zones.
Details how to view and set Proportional (P), Integral (I), and Derivative (D) gains for each temperature zone.
| Maximum Capacity | 1200 kN |
|---|---|
| Test Space Width | 600 mm |
| Testing Machine Type | Universal Testing Machine |
| Test Space | Adjustable |
| Load Frame | Four column |
| Accuracy | ±0.5% of reading from 1% to 100% of capacity |
| Power Supply | 220-240 VAC, 50/60 Hz |