EasyManua.ls Logo

Tisira TOC608 - Timer Operation Periods and Stops

Tisira TOC608
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
pg 16
www.tisira.com | tisira
sounds (2 beeps every 2 seconds) and the “Minute Counter” LED is flashing again. Pressing
any of the buttons stops the signal and the flashing, the LED goes dark and the display reverts
to the time-of-day. If the alarm is not stopped manually, it terminates automatically after 2
minutes. The minute counter can be applied at any time while other functions are operative.
OPERATION PERIOD
In order to set an operation period, the mode button has to be pressed repeatedly until the
“Cooking Time” LED is flashing. Then the desired operation period (time frame between 0.01h
and 10.00h) can be set using the plus and minus buttons. Once adjusted, it will be stored after
approx.. 5 seconds, the “Cooking Time” LED remains illuminated steadily, and the set time
starts running down. The display reverts to the time-of-day. As soon as the operation period
has ended, the relay opens and the alarm signal sounds (4 beeps every 2 seconds) and the
“Cooking Time” LED is flashing again. Pressing any of the buttons stops the signal and the
flashing, the LED goes dark and the relay closes again. If the alarm is not stopped manually,
it terminates automatically after 2 minutes.
OPERATION STOP
In order to set an operation stop, the mode button has to be pressed repeatedly until the
“End Time” LED is flashing. Then the desired operation stop, which is limited to a point being
maximally 23.59 h in the future, can be set using the plus and minus buttons. Once adjusted it
will be stored after approx. 5 seconds, and the “End Time” LED remains illuminated steadily.
The display reverts to the time-of-day. As soon as the operation stop has been reached, the
relay opens and the alarm signal sounds (4 beeps for 2 minutes) and the “End Time” LED is
flashing. Pressing any of the buttons stops the signal and the flashing, the LED goes dark and
the relay closes again.
It is possible to combine the duration and end time in order to program a delayed mode. To do
this, both the operation period and operation stop time have to be set (above). “Cooking Time”
LED and “End Time” LED are illuminated and the baking process will start at a point in time
“operation stop minus operation period”. If a baking process ought to be finished at 12.00 and
shall last 1.30 h, both times have to be set in the respective modes, and the timer will switch
on the oven at 10.30. The timer is capable to avoid conflicts during the programming. (Eg with
an operation period of 60 minutes resp. 1.00 hr set, and the time-of-day being 11.34 o’clock,
then the operation stop can be earliest at 12.34 o’clock.)
NOTICE // A running program can be checked and corrected at any time. In order to avoid
conflicts, it is not possible to set the time of day when an automatic program is active.