48
TTCSP40
In more detail . . .
9. Use a depth gauge
measuring instrument
to check the height of
the depth gauge. Depth
gauge measuring jigs
are available from
most reputable tool
merchants (Fig. 46).
Air lter
Inspect the air lter (6b) regularly. Clean or replace it with a new one if necessary.
1. Loosen the xing screw and remove the top cover (6) (Fig. 47).
2. Remove the air lter (6b).
3. Using the screwdriver (28) separate the air lter (6b) into its two parts and tap them
on a stable surface to remove dust. Use compressed air (max. 3 bar) to remove
stubborn dust.
4. Reassemble the two lter parts and ret the air lter (6b).
5. Attach the top cover (6) and secure it with the xing screw.
47
6b
6
1
2
3
46
Cutting tip
Top plate
Depth gauge
setting 1.27 mm
(0.05")
File position
Cutting length
Care and maintenance

Related product manuals