Injection Molding Machine Chapter 3
V3.0
3-1
Chapter 3: Preparation for installation and test running
1 Placing of the machine
For the convenience of machine operation and maintenance
,
a space of 1~1.5m shall be
reserved around the machine at least
,
if more than two machines are arranged in abreast
with one another
,
the distance between two machines shall be more than 1.5m to facilitate
change of molds.
The minimum space for operation and maintenance are as listed below.
(mm) L
1
2
W
3
4
H
E30 2500 1000 1000 1000 1200 1200 1500
E60 3900 1000 1000 1150 1200 1200 1850
E90 4100 1000 1000 1250 1200 1200 1900
E120 4400 1200 1200 1300 1200 1200 1950
E150 4600 1200 1200 1350 1200 1200 2000
E200 5500 1500 1500 1400 1500 1500 2200
E250 5850 1500 1500 1500 1500 1500 2250
E350 7400 2000 2000 1800 2000 2000 2400
E500 8700 2500 2500 2000 2200 2200 2550
E750 10700 2500 2500 2150 2500 2500 2850
E1000 12000 2700 2700 2450 2700 2700 3050
2 Foundation of the machine
A plant with smooth and solid floor
,
well dried and ventilation condition in conjunction with the
mounting pads are the prerequisites for stable operation of the machine.
The ground flatness between the two ends of machine touch position must within 10mm.