Injection Molding Machine Chapter 3
V3.0
3-13
B)Press any key
,
the screen of maintenance checking points appears.
V1: 0/ 0 0/ 0V2:
0/ 0P1: 0/ 0 P2:100.0mm
100.0mm110.0mm
1.0mm
ACTION STATUS
M:
03D05M07Y
10h250m10s
20°C3W
DAILY CHECK & MAINTENANCE
F2F1 F3 F4 F5 F6 F7 F8
MENU
17
MAINTEN. SUPPORT
I/O
MAINT.
LIST
1.PUSH EMERGENCY BUTTON TO CHECK PUMP STOP.
3.CK. SAFETY DROP BAR MOVES SMOOTH.
4.CK. BARREL COVER IS FIXED.
5.CK. LUB. OF MOVING PARETS ARE OK.
10.CK.HYD.& LUB.OIL ARE ENOUGH.(NO RECYCLE OIL)
7.CK. COLD START PROTECT. TIME AND DANGER
8.CK. TEMP. SET OF HYD. OIL & COLLAR ARE OK.
9.CK IF PUMP HAS ANY NOISE.
6.CK. NO PARTS IS LOOSENED OR ABNORMAL.
11.CK. NO HOSE/PIPE IS LOOSENED/LEAKING.
12.CK. NO AIR IS BLENDED INTO HYD. SYSTEM.
13.CK. ALL GROUDINGS ARE CONNECTED OK.
14.CK. MOLD CLAMP ARE TIGHT.
15.CK. MOLD PROTECTION DEVICE IS OK.
2.CK.NO LEAKING IN HYD. SYSTEM.
1.CK.AND CLEAN HYD. FILTER.
3.CK.AND CLEAN OIL COOLER.
4.CK.NO MOVING PARTS ARE LOOSENED.
5.CK.AND CLEAN ELECTRIC CABINET.
6.TIGHT ALL WIRING TERMALS.
8.TEST PRESS. AND SPEED LINEARILITY.
7.CLEAN AND ADJUST ALL
9.CLEAN WASTE OIL.
HALF YEARLY CHECK AND MAINTENANCE
1.CK.PALTEN'S PARALLELISM.
2.CHANGE HYD. SYSTEM OIL.
3.CK.SCREW/BARREL FUNCTION WELL.
4.MACHINE LEVELING ADJUST.
MONTHLY CHECK & MAINTENANCE
LOG MOLD EXTERN
TEMP. SET OK.
THERMOCOUPLES.
2.CK. I/O 101,103,109 FUNCTION BY OPEN/CLOSE DOOR.
Screen 2-2
C)Press the pump start/stop button on the operation panel to start motor.
8.3 Motor starting inspection
◇
If motor rotation direction is wrong
,
exchange any two of the R
,
S
,
T wires.
※
After inspection
,
press button
on the
panel to stop motor.
WARNING
In confirming motor rotation direction
,
the pump must be at the “
ON
”
position
,
however
,
the pump shall not be in continuous operation for over 3
seconds.
◇
Intermittent Operation
After the completion of the inspection mentioned above
,
press pump on button
on the
operation panel to start pump. After about one second
,
press this button again to stop pump.