Injection Molding Machine Chapter 3
V3.0
3-14
After about 3 seconds
,
press this button again to start the pump
,
repeat this operation for over
10 times for expelling the air being sucked in the pipe.
◇
Continuous Operation
After the completion of the inspection mentioned above
,
press the pump on button on
the operation panel to start pump for continuous operation thus checking the pipelines for
air/oil leakage.
8.4 Check the mold condition
◇
Check if the mold dimensions are listed in the table below
Machine Model
Min. Mold
Hm
×
Vm
Mold
Thickness
T-slot
Space
between tie
bars
hp
×
vp
Mold platen
dimension
Hp
×
Vp
Locating
ring
φ
P(JIS)
Locating
ring
φ
P(EURO)
Nozzle
radius
Rm
60E
190
×
190
100-320
320
×
320 500
×
500
100 125 R15
90E
220
×
220
150-360
400
×
400 590
×
590
100 125 R15
120E
240
×
240
150-425
425
×
425 640
×
640
100 125 R15
150E
250
×
250
150-500
460
×
460 670
×
670
100 125 R15
200E
280
×
280
200-550
510
×
510 760
×
760
150 160 R15
250E
320
×
320
200-600
580
×
580 850
×
850
150 160 R15
350E
380
×
380
300-750
710
×
710 1050
×
1050
150 160 R15
500E
450
×
450
350-900
850
×
850 1250
×
1250
150 200 R15
750E
550
×
550
400-1000
1000
×
1000 1500
×
1500
200 250 R15
1000E
650
×
650
600-1200
1150
×
1150 1700
×
1700
200 250 R15
Remark: Data above may be different to your machine.
Rm
OP
vp
Hp
hp
Vp
T
Hm
Vm
◇
Check the injection volume of the mold
◇
Check the mold opening stroke
◇
Check the ejector pins for meeting the requirement of the mold.
◇