Injection Molding Machine Chapter 4
V3.0
4-18
of clamp close is at 100.0.
C
TIME
:
use timer to control core in/out operation.
D
COUNT
:
use counter to control core in/out
,
the user has to install the core counting
detection device to core in and out I/O.
If only one counting device is used
,
connect it to CORE IN I/O and short bridged IN and
OUT I/O.
E
I/O
monitor
:
use limit switch to control the core in/out position
,
the user has to install limit
switch at the corresponding I/O point. (Take off bridges on terminal board)
2.7.1
All timer
,
counter
,
limit switch must be made to complete core process. When only limit
switch is used
,
the timer and counter shall be set to 0. When limit switch is not used
,
I/O.131
,
132
,
133
,
134
,
331
,
332 and C must be short-circuited.
2.7.2 Unscrewing
If core is used as unscrewing
,
COUNT value takes first priority
,
i.e. once counting is finished
,
and unscrewing stops no matter what the timer is.
In order to get precise stop position
,
set CORE VALVE OFF DELAY to 0 and CORE SPEED
RAMP to 0 and runs with low speed.