Injection Molding Machine Chapter 4
V3.0
4-27
residence time in barrel. The best setting is charging just finished before cooling is over.
2.12.2 Setting suck back
E
Suck back is controlled by position or timer (the timer setting is on the CHARGE PAR.
screen)
,
it will stop on either condition is satisfied.
Suck back setting value is charge stop position + suck back distance
,
for instance
,
if the
charge end is set at 50.0
,
and suck back setting at +3.0
,
the final position shall be at 53.0.
If suck back before charge function is on
,
screw will suck back at the setting distance
before charge starts.
2.12.3 Carriage setting
F
Speed 1 to speed 2(low speed) position is usually set to the position of 20.0~50.0 before
nozzle contacts with the mold.
G
Carriage forward stop position F.W. END is usually set to the position plus 1.0mm which
nozzle hits against the mold.
H
Carriage retract limit position B.W. END
:
In automatic or semi-automatic mode
,
when
carriage movement function is ON
,
this position is carriage automatic retract stop position.