residence time in barrel. The best setting is charging just finished before cooling is over.
2.12.2 Setting suck back
Suck back is controlled by position or timer (the timer setting is on the CHARGE PAR.
screen)
it will stop on either condition is satisfied.
Suck back setting value is charge stop position + suck back distance
for instance
if the
charge end is set at 50.0
and suck back setting at +3.0
the final position shall be at 53.0.
If suck back before charge function is on
screw will suck back at the setting distance
before charge starts.
2.12.3 Carriage setting
Speed 1 to speed 2(low speed) position is usually set to the position of 20.0~50.0 before
nozzle contacts with the mold.
Carriage forward stop position F.W. END is usually set to the position plus 1.0mm which
nozzle hits against the mold.
Carriage retract limit position B.W. END
In automatic or semi-automatic mode
when
carriage movement function is ON