1500-LB PORTABLE
MOTORCYCLE/ATV LIFT
1,5
PRODUCT MANUAL
v2023.06.18
TMG-1500PML
Please read and understand the product manual completely before assembly
Check against the parts list to make sure all parts are received
Wear proper safety goggles or other protective gears while in assembly
Do not return the product to dealer. They are not equipped to handle your requests.
Missing parts or questions on assembly?
Please call: 1-877-761-2819 or email: cs@tmgindustrial.com
Question and Answer IconNeed help?

Do you have a question about the TMG TMG-1500PML and is the answer not in the manual?

Overview

The TMG-1500PML is a 1500-lb portable motorcycle/ATV lift designed for professional and personal use in indoor environments. This product manual provides comprehensive instructions for installation, operation, and maintenance, emphasizing safety and proper usage to ensure longevity and prevent injury or damage.

Function Description

The TMG-1500PML lift is engineered to safely raise and lower motorcycles and ATVs, providing an elevated work platform for maintenance, repairs, and inspections. It features a pneumatic-hydraulic system for lifting, controlled by a foot pedal, and a mechanical locking mechanism to secure the lift at desired heights. The lift is portable, allowing for flexible placement within a workshop or garage. Optional side extensions and a wheel vise enhance its versatility, accommodating a wider range of vehicles and ensuring stable positioning during operation. The drive-up ramp facilitates easy loading of vehicles onto the lift deck.

Important Technical Specifications

  • Main Lifting Table Dimensions: 28" W x 78 1/2" L
  • Width with Side Extensions: 48" W
  • Extended Approach Ramp: 10" W x 25 1/2" L
  • Lowered Height: 7 1/4"
  • Capacity: 1500 lb
  • Hydraulic Tank Capacity: 1.5L
  • Hydraulic Working Flow: 1/8-1/4GPM
  • Hydraulic Fluid Model: #15-#32
  • Air Supply Requirement: 90 - 160 PSI maximum shop air
  • Safe Operating Temperature Range: 41° F - 104 °F

The lift's construction includes a robust deck plate, scissor mechanisms (inner and outer), and a hydraulic cylinder for reliable lifting. The pump assembly, detailed in the manual, is crucial for the hydraulic operation. Safety features include a safety latch, quick pins for securing extensions, and various bolts and nuts designed for secure assembly.

Usage Features

The TMG-1500PML is designed for straightforward operation, though it requires careful adherence to safety protocols.

  • Installation: The manual outlines a step-by-step installation process, starting with site selection, which requires a level concrete floor in good condition. It emphasizes checking all parts against the list and wearing appropriate safety gear. The installation includes attaching side extensions (optional), a wheel vise, and drive-up ramps.
  • Lifting and Lowering: To lift, the lock release lever is placed in the lower (locked) position, and the pump foot pedal is pressed. Once the desired height is reached, the lift is lowered slightly into a locked position. To lower the lift, it must first be raised about 1" off the locked position, the lock release lever moved to the upper (unlocked) position, and the release pedal on the pump assembly pressed and held.
  • Vehicle Loading: Vehicles should be pushed, not ridden, onto the lift via the drive-up ramps. The wheel vise is used for temporary holding, and straps must be used to securely fasten the motorcycle to the lift table. Loads must always be centered on the table.
  • Safety Mechanisms: The mechanical lock is critical for maintaining the lift in an elevated position, as hydraulics are for raising and controlled lowering only. The manual stresses the importance of visually confirming that the safety lock is engaged before working under the elevated lift.
  • Work Environment: The lift is intended for indoor use only. Adequate ventilation is required when working on internal combustion engines. The work area should be clean, well-lit, and free from clutter to prevent injuries.

Maintenance Features

Regular maintenance is crucial for the safe and efficient operation of the TMG-1500PML lift.

  • Lubrication: All moving parts are lubricated at the factory and should be re-lubricated every 6 months to prevent galling. The cylinder rod should be lightly oiled when it becomes dry.
  • Inspections: A daily inspection of the lift is recommended before use. This includes checking for alignment of moving parts, breakage, or any condition that might affect operation. Safety devices, operating controls, and lift arms must be inspected. Pivot shaft set screws should be checked frequently for tightness.
  • Part Replacement: Only authorized or approved replacement parts should be used for service and maintenance. Repairs should only be completed by a qualified lift technician.
  • Cleanliness: The lift should be kept clean for better and safer performance. Control handles and buttons should be dry, clean, and free from grease and oil. All decals on the unit must be kept clean and visible.
  • Hydraulic System: The manual provides detailed breakdowns of the main parts, cylinder, and pump, facilitating identification and replacement of components if needed. This includes specific parts for the hydraulic cylinder (e.g., piston, Y-ring, flow regulator valve) and the pump assembly (e.g., plungers, springs, valves, seals).

The manual strongly emphasizes reading and understanding all instructions and safety warnings before operating the lift. It highlights the owner's responsibility to ensure proper installation, training of operators, and regular maintenance to uphold safety standards and product warranty. Failure to comply with these instructions can lead to serious personal injury, death, or property damage.