■Wiring
■Terminal explanation
Communication Please connect the terminal of A and B rightly.
(Please use a converter when it is not RE-485)
Output
(Right reverse
change is possible)
Relay point of
contact
C: Common, No: Normal open
SSR driving Please connect directly with INPUT+ and - by the
side of SSR.
Transmission,
Open collector
Please be connected to polarity of + and - with
care
CT Please connect a specied current transformer directly. (CTL-6-P-H)
PV input/
AI input
Thermocouple Please be connected to polarity of + and - with
care
Current/
voltage
Please be connected to terminals A, B and b with
care
DI COM: Common (The polarity can be switched)
AI input Please be connected to polarity of + and - with care
1
2
3
4
5
6
7 Output3※
Output4※
Output34※
8
11
12
9
10
Output2
Power
Input
7
8
9
7
8
9
NO
NO
C
Output1
A
B
13
14
15
16
17
18
Communication(RS-485)
CT1
CT1
CTInput
CT2
CT2
b
B
A
DIInput
15
16
17
18
DI1
DI1(COM)
DI2
DI2(COM)
11
12
10
11
12
10
11
12
10
3
4
5
6
C
NO
C
NO
3
4
5
6
Other
Output
Relay
Output
Other
Output
Relay
Output
Other
Output
Relay
Output
OpenCollector
Output
Relay
Output
RTD TC/10mV
PV
I/V
Power
3
4
5
6
7
8
9
10
11
12
RTD I/VTC/10mV
3
4
5
6
7
8
9
10
11
12
C
NO
C
NO
C
NO
C
NO
C
NO
22
23
24
22
23
24
22
23
24
b
B
A
19
20
21
NO
NO
C
19
20
21
1
2
3
4
5
6
7
8
9
10
11
12
Output2
Output5
Output6
Output7
Output1
13
14
15
16
17
18
19
20
21
22
23
24
CT1
CT1
CT2
CT2
Output3※
Output4※
Output34※
AIinput(Voltage/current)
Input
25
26
27
28
29
30
31
32
33
34
DI1
DI1(COM)
DI2
DI2(COM)
DI3
DI4
DI3,4(COM)
DIInput
CT
A
B
Communication(RS-485)
OpenCollector
Output
Relay
Output
PV
Power
3
4
5
6
7
8
11
12
13
3
4
5
6
7
8
C
NO
C
NO
C
NO
11
12
13
NO
NO
C
23
24
NO
C
23
24
1
2
3
4
5
6
7
8
Output2
Output5
Output1
17
18
19
20
21
22
23
24
A
B
CT1
CT1
CT2
CT2
CTInput
Output7
Communication(RS-485)
19
20
21
22
23
24
DI1
DI1(COM)
DI2
DI2(COM)
DI3
DI3(COM)
DIInput
9
10
11
12
13
14
15
16
Output3※
Output4※
Output34※
AIinput(Voltage/current)
Input
14
15
16
RTD
b
B
A
14
15
16
TC/10mV
PV
14
15
16
I/V
OpenCollector
Output
Relay
Output
OpenCollector
Output
Relay
Output
TTM-204
TTM-205、209
TTM-207
※Please use less than 6mm width terminal
※ Output 3 to 7 (Terminals 19 to 21and 7 to 12) are possible to select from either relay output or open collector.
※ Output 3 to 5 and 7 (Terminals 11 to 13, 7 to 8, 23 to 24) are possible to select from either relay output or open collector.
※ Output 3 and 4 (Terminals 7 to 9) are possible to select from either relay output or open collector.