AIR COMPRESSOR
1/3HP/2-GALLON
IMPORTANT: READ THIS OPERATOR’S MANUAL BEFORE USING
OPERATOR’S
MANUAL
ITEM# AT01101
SKU# 207-1525

Questions and Answers

  • C
    Clayton SandersAug 6, 2025
    What to do if my Tool Shop AT01101 Air Compressor pressure relief valve opens?
    • V
      Vickie RobertsAug 7, 2025
      If the pressure relief valve opens, it means the tank pressure has exceeded its normal rating. Replace the pressure switch to resolve this. It could also mean that the pressure switch is stuck, in which case, you should also replace it.
  • R
    roseharringtonAug 12, 2025
    What to do if the regulated pressure gauge reading drops when using my Tool Shop AT01101 Air Compressor?
    • N
      Natasha CantuAug 13, 2025
      This can be normal. If the pressure drops too low, adjust the regulator while the accessory is in use. However, if the compressor is not large enough for the tool, check the air requirement of the accessory. If it's higher than the CFM and pressure supplied by the compressor, you'll need a larger compressor. Most accessories are rated at 25% of actual CFM while running continuously.
  • W
    williamschadAug 25, 2025
    Why is air leaking from the regulator on my Tool Shop Air Compressor?
    • A
      asmithAug 25, 2025
      Air leaks or pressure regulation issues often stem from dirty or damaged internal parts of the regulator. The solution is to replace the regulator or its internal parts.
  • L
    landersonOct 30, 2025
    Why is my Tool Shop AT01101 not building enough pressure?
    • C
      coxkyleOct 30, 2025
      Several factors can cause low pressure. First, ensure the tank drain valve is closed tightly. Leaking fittings should be checked with soapy water and tightened or resealed, but avoid overtightening. Also, a restricted air intake requires you to clean or replace the air filter element. If you are using air excessively for prolonged periods, decrease the amount of air used. The compressor might not be large enough for your needs, so verify that the air requirement of your accessory isn't higher than what the compressor supplies. Accessories are typically rated at 25% of actual CFM when running continuously. Inspect the air hose for holes and replace if needed. Immediately replace the tank if it is leaking and do not attempt to repair it. Finally, blown seals, valve leaks, or a leaking/worn p...
  • K
    kimberlysnyderNov 18, 2025
    How to fix a Tool Shop Air Compressor motor that will not run?
    • J
      Joshua GriffinNov 18, 2025
      First, the motor will start automatically when tank pressure drops below the pressure tank's kick-in pressure. If the motor overload protection has tripped, let the motor cool off, and the overload switch will automatically reset, which may take several minutes. Check for a blown fuse or tripped circuit breaker, and replace or reset it, ensuring you do not use a fuse or circuit breaker with a higher rating than specified for your branch circuit. Ensure you are using the proper fuse; a 'Fusetron' type T is acceptable. Verify there is no low voltage and that the extension cord is the correct size. Disconnect other applications from the circuit to operate the compressor on a dedicated circuit. Also, bleed line by moving pressure switch lever to OFF position before restarting. If bleeder valve...

Summary

Safety Guidelines

Fire, Electrical, and Bursting Hazards

Warnings about flammable liquids, ventilation, electrical shock, and tank integrity.

Personal Injury and Burn Prevention

Safety measures for servicing, handling hot parts, and eye protection.

Breathing and Eye Injury Risks

Safety regarding toxic materials, air inhalation, and eye protection.

Operational Cautions

Daily checks, ventilation, cord protection, hearing protection, stable operation.

Basic Compressor Features

Electric Motor & Pump Function

Motor overload protection and pump air compression mechanism.

On;Off Switch and Operation

Controls compressor start-up, automatic shut-down, and safe off-state.

Air Outlets and Pressure Gauges

Connects air hose; displays regulated and tank air pressure.

Air Pressure Regulator Usage

Adjusts air pressure for tools; requires careful setting.

Pressure Relief Valve & Air Tank

Prevents over-pressurization; stores compressed air.

Air Tank Drain Valve Operation

Removes moisture from the tank; requires caution with pressure.

Power Cord & Grounding Requirements

Proper cord use and grounding for electrical safety.

Operation

Daily Start Up Procedure

Step-by-step guide for starting the air compressor.

Shutdown Procedure

Steps to safely turn off and prepare the compressor for storage.

Exploded View

Parts List

Detailed list of all components with part numbers and quantities.

Tool Shop 2 Gal Air Compressor Warranty

Tool Shop AT01101 Specifications

General IconGeneral
BrandTool Shop
ModelAT01101
CategoryAir Compressor
LanguageEnglish