thoroughly removed from all surfaces.
2. Maintain a distance of 2cm (0.7 inches) between the unit and walls or other objects for ventilation.
Increase this distance if the obstacle is a heat source.
Operation
1. General
ECS-10HT1 could be specially used in kitchen cabinet and air curtain cabinet, unit Celsius and
Fahrenheit could be switched by menu, Max. two channel of sensors separately used for cabinet
temperature adjustment and defrost control; Compressor and defroster relay could select the
specification 30A-10A, or 17A-10A; The display of the controller could be selected as cabinet
temperature or evaporator temperature; split design between control board and display panel, very
convenient for repairing and replacement.
2. Technical parameters
2.1 Measuring range-50+90 or -58194(only when sensor calibration is 0)
2.2 Resolution1or 1℉;
2.3 Accuracy-4050,±1 5170 ,±2others,±3
or -40122,±2123158,±4others,±6
2.4 Cabinet temperature control range-5090 or -58194
2.5 Power supply220VAC50/60Hz
2.6 Power consumption<3W
2.7 Output capacity
Refrigeration30A/240VACnormal open directly drive a single phase 1.5HP220VACload
(or optional) 17A/240VACnormal open directly drive a single phase 1.0HP220VACload
Defrost or lighting relay10A/240VACnormal open directly drive heater strip Max.1200W
(220VAC);
(or optional) 05A/240VACnormal open directly drive heater strip Max.500W (220VAC).
Note: Defrost or lighting relay could be used as lighting relay or defrost relay.
When parameter U3=0, defrost/lighting relay is used as defrost output, and it has no function of lighting
control at this time;
When parameter U3=1, defrost/lighting relay is used as lighting output, and it has no defrost function,
defrost is proceeded as off-cycle defrost.
2.8 Input terminal: cabinet sensor, evaporator sensor (optional)
2.9 Work ambient temperature0℃~55
2.10 Storage temperature-25℃~75
2.11 Relative humidity20%85%non condensing
2.12 Front panel protection level: IP65
3. Operation and display panel