Conducting Battery Test
The battery testing function is only applicable to 12V lead-acid batteries. Only use the
battery clamps to connect to the battery terminals when conducting a battery test.
First, tap Test Management, then tap Battery Test. Select the corresponding battery type.
The specific battery type is usually listed on the battery label. Select the corresponding
battery standard. The specific battery standard will also be listed on the battery label.
Refer to the following table for specific battery standards and test ranges. The battery
tester will test each battery according to the selected system and rating.
Standard
Description
Measuring
range
CCA
Cold Cranking Amps, specified by SAE & BCI, most
frequently used value for starting battery at 0°F (-18°C).
100-2000
BCI
Battery Council International standard.
100-2000
CA
Cranking Amps standard, effective starting current value at
0°C.
100-2000
MCA
Marine Cranking Amps standard, effective starting current
value at 0°C.
100-2000
JIS
Japan Industrial Standard, displayed on the battery as
combination of the numbers and letters, e.g. 55D23,
80D26.
26A17-245H52
DIN
German Auto industry Committee Standard.
100-1400
IEC
International Electro Technical Commission Standard.
100-1400
EN
European Automobile Industry Association Standard.
100-2000
SAE
Society of Automotive Engineers Standard.
100-2000
GB
China National Standard.
30-220Ah
Next, input the battery capacity value and tap Battery Test to start the test. After several
seconds, the test result will be displayed.
To conduct a cranking test or charging text, please follow the on-screen instructions.