WARRANTY
Voltage......................................................................................... 120VAC, 60Hz
Resistive………......................…...…….…………..........................…15A, 1800W
Tungsten....................................................................................................1200W
Standard Ballast.......................................................................................1200VA
LED..............................................................................................................150W
Motor ……...........………................……..........................……….………......1/2Hp
• Turn the Load ON/OFF and switch between Automatic and Manual modes by pressing the
“M/R” (mode) button.
• The large and easy-to-read LCD screen displays the current day of week, time, Auto/
Manual mode, whether the Load is ON or OFF, and the program settings.
• The Timer can be programmed up to 18 ON and 18 OFF settings.
• Random feature (RND) turns ON/OFF the Load at a random time, 30 minutes within the
programmed time.
• DST: Daylight Savings Time.
FEATURES
INSTALLATION INSTRUCTIONS
Model: TGT07
DIGITAL 7-DAY TIMER
DUAL OUTLET HEAVY DUTY PLUG-IN
R
PRG
DAY
HOUR
HOUR
MIN
DST
RND
MAN
A
OFF
MO TU WE TH FR SA SU
PROG
M/R
MAIN SCREEN BUTTONS AND INDICATORS
CLOCK SCREEN BUTTONS AND INDICATORS
HOUR
DST
M/R
MIN
RND
PRG
R
PRG
PRG
HOUR
DST
MIN
RND
DAY
1. Indicates the day of the week.
2. DAYLIGHT SAVINGS TIME indicator.
• DST displayed = ON
• DST not displayed = OFF
3. Indicates the status of connect light(s) or load(s): ON/ OFF.
4. DAY button. This button has no function on main screen.
5. HOUR button. Used to turn Daylight Savings ON/ OFF. Hold down for 6
seconds to turn Daylight Savings ON or OFF.
6. AUTO/ MANUAL indicator. Indicates Manual operation mode and Automatic timer
controllet mode
7. Random Mode Button. Used to turn Random Mode ON/ OFF. Hold down
for 6 seconds to turn Random Mode ON or OFF.
8. RESET button: Push to reset all settings to Factory Default. Press and
immediately release.
9. PROGRAMMING button. Press once to Program the Clock. Press two
times to Program the ON and OFF times.
10. MANUAL ON/OFF button. It’s used to manually turn the light(s)/ load(s) ON/ OFF.
11. MODE button. Press the button to switch between Manual operation mode
and Automatic timer controlled mode.
Automatic Mode: In this mode, the timer will run the programs that you
have scheduled. It will automatically turn the lights ON or OFF based
on all your programs.
• Manual: In this mode, the timer WILL NOT run the programs that you have
scheduled. You will only be able to operate the lights using the MAN button.
12. AM/ PM indicator
13. CLOCK
14. RANDOM mode indicator.
• RND displayed = ON
• RND not displayed = OFF
1. Indicates the day of the week.
Options are:
MO = MONDAY FR = FRIDAY
TU = TUESDAY SA = SATURDAY
WE = WEDNESDAY SU = SUNDAY
TH = THURSDAY
2. DAY button. Press to scroll through the days.
3. HOUR button. Press to change the hours. The clock is in 12 hour format.
4. MINUTES button. Press to change the minutes.
5. RESET button: Push to reset all settings to Factory Default.
6. PROGRAMMING button. When you are in the clock screen, pressing the
once will enter the Programming for the ON and OFF times.
7. MANUAL button. Press to exit programming and return to main screen.
8. MODE/ RECALL button. This button has no function on the clock screen.
9. AM/ PM indicator.
10. CLOCK.
This device is warranted to be free of material and workmanship defects for 1 year from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim.
ALL claims must be verified and approved by Top Greener, Inc. Warranties from other Top Greener products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction,
failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Top Greener shall not be liable to the purchaser or
end user customer of Top Greener products for direct, indirect, incidental, or consequential damages even if Top Greener has been advised of the possibility of such damages. Top Greener’ total liability under this
or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
R
PRG
DAY
HOUR
MIN
DST
RND
MAN
P
ON
WE
AUTO
M/R
MAN
R
PRG
DAY
HOUR
MIN
DST
RND
MAN
A
MO
CLK
M/R
DST RND
1.
10.
9.
8.
7.
4.
3.
2.
6.
5.
1.
13.
12.
11.
10.
7.
5.
4.
9.
8.
14.
2.
6.
Question and Answer IconNeed help?

Do you have a question about the Topgreener TGT07 and is the answer not in the manual?

Overview

The TGT07 Digital 7-Day Timer is a heavy-duty, dual-outlet plug-in device designed for automatic control of electrical loads. It offers a comprehensive set of features for scheduling and managing connected devices, making it suitable for various applications in homes and offices.

Function Description:

The primary function of the TGT07 timer is to automatically turn connected electrical loads ON and OFF according to a user-defined schedule. It operates on a 7-day cycle, allowing for different programming on each day of the week. The timer supports up to 18 ON and 18 OFF settings, providing extensive flexibility for scheduling.

The device features a large, easy-to-read LCD screen that displays crucial information at a glance. This includes the current day of the week, the precise time (in 12-hour format with AM/PM indicator), the current operating mode (Auto/Manual), and the ON/OFF status of the connected load. When in programming mode, the screen also shows the selected program number and whether it's an ON or OFF setting.

Users can switch between Automatic and Manual modes using the "M/R" (mode) button. In Automatic mode, the timer executes the programmed schedule, turning lights or other loads ON and OFF as planned. In Manual mode, the timer's scheduled programs are bypassed, and the user can manually control the load's ON/OFF status using the "MAN" button. This provides immediate control when needed, overriding the automatic schedule.

A unique "Random" feature (RND) enhances security by turning the load ON/OFF at random times within a 30-minute window of the programmed ON/OFF times. This can simulate occupancy, deterring potential intruders.

The timer also includes a Daylight Savings Time (DST) feature, allowing users to easily adjust the clock forward or backward by one hour. This is a convenient feature for seasonal time changes, though it does not automatically adjust.

Important Technical Specifications:

  • Voltage: 120VAC, 60Hz
  • Resistive Load: 15A, 1800W
  • Tungsten Load: 1200W
  • Standard Ballast Load: 1200VA
  • LED Load: 150W
  • Motor Load: 1/2Hp

These specifications indicate that the TGT07 is a robust device capable of handling a variety of electrical loads, from standard lighting and appliances to motors, within its specified power limits. The dual outlet design allows for controlling two separate devices simultaneously, provided their combined load does not exceed the timer's maximum capacity.

Usage Features:

The TGT07 timer is designed for user-friendly operation with clearly labeled buttons and indicators.

Main Screen Buttons and Indicators:

  • Day of the Week Indicator: Shows the current day (MO, TU, WE, TH, FR, SA, SU).
  • DST Indicator: Displays "DST" when Daylight Savings Time is ON.
  • ON/OFF Indicator: Shows whether the connected load is ON or OFF.
  • AM/PM Indicator: Displays "A" for AM and "P" for PM.
  • CLOCK: Displays the current time.
  • RND Indicator: Displays "RND" when Random mode is ON.
  • AUTO/MANUAL Indicator: Shows "AUTO" for Automatic mode or "MAN" for Manual mode.
  • M/R (Mode) Button: Switches between Manual and Automatic operation modes.
  • MAN (Manual ON/OFF) Button: Manually turns the light(s)/load(s) ON or OFF.
  • PRG (Programming) Button:
    • Press once from the main screen to enter Clock programming.
    • Press twice from the main screen to enter ON/OFF time programming.
    • In programming mode, it scrolls through ON/OFF programs.
    • From programming mode, it can also exit programming and return to the main screen.
  • DAY Button: Used in programming to scroll through days of the week.
  • HOUR/DST Button:
    • Changes the hour in clock/program settings.
    • Hold for 6 seconds from the main screen to turn Daylight Savings ON/OFF.
  • MIN/RND Button:
    • Changes the minutes in clock/program settings.
    • Hold for 6 seconds from the main screen to turn Random Mode ON/OFF.
  • R (Reset) Button: Pushed with a small object to reset all settings to Factory Default.

Programming the Timer:

  1. Setting Current Time and Day (CLOCK):

    • Press PRG once. The "CLK" icon appears.
    • Use HOUR and MIN buttons to set the time, ensuring correct AM/PM.
    • Use DAY button to select the current day.
    • Press MAN to return to the main screen.
  2. Adding ON and OFF Times:

    • Press PRG twice. "ON 1 PROG" will appear.
    • Set the ON time using HOUR and MIN buttons.
    • Select the day(s) for this program using the DAY button. (Pressing DAY until all days are displayed applies the program to all days as one program).
    • Press PRG again. "OFF 1 PROG" will appear.
    • Set the corresponding OFF time and day(s) using HOUR, MIN, and DAY buttons.
    • Repeat the process by pressing PRG to add more ON/OFF programs (up to 18 pairs).
    • Press MAN to return to the main screen.

Bypassing a Saved Program:

  • Press PRG to scroll to the ON or OFF program to be bypassed.
  • Press M/R once. The program will be bypassed. Remember to bypass both ON and OFF programs.
  • Press MAN to return to the main screen.

Daylight Savings Time (DST):

  • To Enter DST: From the main screen, hold HOUR/DST for 5 seconds until "DST" appears. The clock will adjust forward by 1 hour.
  • To Exit DST: From the main screen, hold HOUR/DST for 5 seconds until "DST" is no longer displayed. The clock will adjust back by 1 hour.

Random Mode:

  • To Enter Random Mode: From the main screen, hold MIN/RND for 6 seconds until "RND" appears.
  • To Exit Random Mode: From the main screen, hold MIN/RND for 6 seconds until "RND" no longer appears.

Operating the Timer (Automatic/Manual Modes):

  • From the main screen, press M/R to toggle between "AUTO" (Automatic) and "MAN" (Manual) modes.
  • In Automatic mode, the timer runs scheduled programs.
  • In Manual mode, programs are ignored, and the MAN button controls the load.

Maintenance Features:

  • Rechargeable Backup Battery: The timer has a built-in rechargeable backup battery that retains all programming during power outages. This ensures that schedules are not lost even if power is interrupted.
  • Reset Function: The "R" (Reset) button allows users to reset all settings to Factory Default. This is useful for troubleshooting or when programming the timer for the first time. To reset, use a small object (like a paper clip) to press and immediately release the "R" button. The display will flash to confirm the reset.
  • Time-out Feature: In programming mode, if no buttons are pressed within 12 seconds, the display will automatically return to the main screen, preventing accidental changes or battery drain.

The TGT07 Digital 7-Day Timer is a versatile and reliable device for automating electrical loads, offering convenience, energy savings, and enhanced security through its various programming and operational features. Its robust specifications make it suitable for a wide range of applications.