PROGATE
Cellular Gate Access Controller
Quick setup guide
GSM gate controller PROGATE could be used for remote
control of gates, barriers and other equipment. With free
short call, SERANOVA app, SMS, iButton keys,
RFID cards, Wiegand keypad code.
1. Specifications
Technology platform: LTE CAT-1 or GSM/GPRS/EDGE
Administrators: up to 8 can receive SMS and Call
Users database (Phones, iButton, RFID, Codes): up to 800
Power supply:
AC 10-24 V 50 Hz ~ 200 mA max / DC 10-30 V 200 mA max
Current consumption in idle state w/o external devices
connected: up to 50mA
Number of inputs: 2
Zone: NC, NO or EOL=5.6kΩ (settable)
Analog: 0-30V (settable)
Number of I/O input/output: 2
Open Drain 24V/1A
Zone: NC, NO or EOL=5.6kΩ (settable)
Relay Output: 1A 30 V DC, 0.5A 125 V AC
Wiegand interface:
26-bit Wiegand format
8-bit Keypad PIN/CODE format
Maxim’s 1-Wire® interface:
iButton Keys DS1990A; temperature sensors DS18b20
Aosong 1-wire Humidity/Temperature Sensor AM23xx
Buffer for unsent events: up to 3072 events
Nonvolatile flash Event LOG: up to 3072 events
Dimensions: 73x62x26mm
Operating temperature range: -20…+55 °C
Module weight: 70g
Package weight: 90g
Humidity: 0-90% RH @ 0… +40°C (0-90% RH @ +32…
+104°F) (non-condensing)
2. LED indication
Watchdog blinking, on
50ms,off for 1000ms
The module is functioning.
Flashes, remains lit for
50ms, turns off for 300ms
Modem is being registered to the
network.
Blinking fast, 50ms on,
and off for 50ms
PIN code of SIM card error. PIN
code request should be removed
Modem failed to register to the
network.
Module contains unsent reports to
the user or to the server.
All reports has been send.
3. Quick set up of the controller
1. Insert nano-SIM card. Turn off PIN code
requests
2. Screw GSM antenna,
3. Connect power supply 10-30VDC
Note: the USB power supply can only be used for
configuration. It is not sufficient to power the modem.
4. Call to the module.
Note: The first one to call the controller will become the system administrator.
Device will turn on the RELAY output for 2 seconds. The phone number will be
stored in the module’s memory automatically. The caller will receive a greeting
SMS with the IMEI of the module. At this moment all calls from different phone
number will be rejected. The controller can be installed without any additional
configuration if such operation mode is acceptable.
5. Configuration and control methods:
SERA2 - configuration software via USB or internet remote
https://www.topkodas.lt/Downloads/SERA2_Setup.exe
SERANOVA - Free WEB app https://seranova.eu/login
SMS – configuration with INST commands.
Complete SMS commands can be found in full
Installation & Programming manual
Manualhttps://www.topkodas.lt/product/progate-4g
3.1. Add/Edit/Delete Users to receive SMS/DIAL
Using SMS commands:
Add/Edit User SMS/DIAL communication:
INST000000˽001˽N#TEL#SMS#DIAL#
001= command; N = user index 1-8; TEL = telephone number international format without (+); SMS =
notifications event filter; DIAL = event filter; #= delimiter
Event filter from left to right 0-disabled; 1-enabled:
1. Alarm/Restore (CID 100 group)
2. System Open/Close (CID 400 group)
3. System Troubles (CID 300 group)
4. Sensor1-Sensor32 Alarm/Restore
5. Test Events (CID 600 group)
6. Other Events
7. Input/Zone1 Alarm/Restore
8. Input/Zone2 Alarm/Restore
9. Input/Zone ...n etc.
e.g. INST000000˽001˽1#37066666666#0000000000#0000000000#
This example disable all SMS and DIAL notifications.
Delete SMS/DIAL user by index:
INST000000˽002˽ID ID = user index number from 1 to 8
Add user to remote control output Arm/Disarm:
INST000000˽004˽ID#TEL#OUT#OPT#NAME#
004= command code (enter user‘s telephone number for remote control via short call)
ID = user index 1-800, TEL = user‘s phone #; OUT= output number 1-32. 0-disabled
OPT = 0 – disabled 1 – enabled, Sequence from the left to the right
1. User Enabled
2. Enable Arm/Disarm system by call
NAME = User Name
e.g.INST000000˽004˽1#37066666666#1#10#Jon#
Delete all user data by index:
INST000000˽006˽ID ID = user‘s index number from 001 to 800.
Using SERA2 Configuration software via USB or internet:
3.2. Setting parameters using SERA2 software
With SERA2 software you can change the controller’s settings
(if default settings are not enough)
1. Download the configuration software SERA2 from
https://www.topkodas.lt/downloads/ and install it.
2. Connect the controller to a computer using a mini USB
cable.
3. Launch the configuration software SERA2. The program will
automatically recognize the connected device and will
4. Automatically open the controller configuration window.
5. Click Read to see current controller parameters
Note: The button [Read] will make the program read and show
the settings currently saved on the device.
The [Write] button will save the settings to the flash memory.
The button File> [Save] will save the configuration to file for later
use. This allows to quickly configure multiple devices with the
same settings.
The button File> [Open] will allow to choose a configuration file
and open saved settings.
To revert to the default settings, go to Update FW without
checking the Preserve settings checkbox.
4. SERANOVA app
With SERANOVA app users will be able to administrate users
and control remotely. They will also be able to see the system
state and receive push Notifications, all event messages.
Free WEB SERANOVA app https://seranova.eu/login
Scan QR code and install SERANOVA app.
SERANOVA
Login. New Customer? Please create an account.