TOPVERT G1/H1/P1 Series
E-17
21: Accumulated power-up Day (day)
22: Accumulated power-up time (hh:mm)
23: (Factory Reserved)
24: (Factory Reserved)
25: (Factory Reserved)
26: The signal of AI1 analog input (Vdc)
27: The signal of AI2 analog input (mAdc)
28: The signal of AI3 analog input (Vdc)
29: (Factory Reserved)
30
33: (Factory Reserved)
34: Over-Torque detection level 1 (Pr5-16)
35: Motor 1 Auto torque boost (Pr5-01)
36~37: (Factory Reserved)
38: Stall level while run in constant torque area
(Pr5-12)
39
52: (Factory Reserved)
53: Output power (kW)
54: Output capacity (kVA)
55
(Factory Reserved)
56: The temperature of IGBT module--TH1 ( °C)
57: The temperature of environment or fin (TH2) (°C )
58: (Factory Reserved)
59: (Factory Reserved)
60: Drive overload accumulated time (OL)
61~63
(Factory Reserved)
64: DC Bus voltage upon a fault (Vdc)
65: Output voltage upon a fault (Vac)
66: Output frequency upon a fault (Hz)
67: IGBT module temperature upon a fault ( °C)
68: Output current value upon a fault (Aac)
69
Temperature of Fin or environment
upon a fault ( °C)
70~86
(Factory Reserved)
87: DC Bus ripple voltage (Vdc)
88: PG frequency (Hz)
Pr0-08
User-Defined coefficient K
0
39 (no use)
0
40
60000 (the corresponding value for Pr1-00-- the
max. frequency).
Pr0-09
The decimal places
0~3 (0=Without d.p., 1= 1 digit d.p., 2=2 digit d.p.,
3=3 digit d.p.)
0
Pr0-10
Firmware version Read-only x.xx
Pr0-11
EPROM store set
Bit0
(bxxxx0)
0
FWD/REV direction command will
be store
b00000
1
FWD/REV direction command not
store
Bit1
(bxxx0x)
0
Frequency command from PU will
be store
1
Frequency command from PU not
store
Bit2
(bxx0xx)
0
RS-485 frequency command will
be store
1
RS-485 frequency command not
store
Bit3
(bx0xxx)
0
Up/Down frequency command will
be store
1
Up/Down frequency command not
store
Bit4
(b0xxxx)
0
Changed parameter will be store
1
Changed parameter not store