EasyManua.ls Logo

TOPTEK TOPVERT E1 Series - Page 29

Default Icon
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOPVERT G1/H1/P1 Series
E-28
Pr5-23 Over-Torque Detection Time 2 (ot2) 0.0
60.0 Sec 0.1
Pr5-24
{Pr5-21}
Most Recent Fault Record
0: no fault
0
Pr5-25
{Pr5-22}
2nd Most Recent Fault Record
1: oC (over-current)
Pr5-26
{Pr5-23}
3rd Most Recent Fault Record
2: oU (over-voltage)
Pr5-27
{Pr5-24}
4th Most Recent Fault Record
3: GF (ground fault)
Pr5-28
5th Most Recent Fault Record
4: SC (IGBT failure)
Pr5-29
6th Most Recent Fault Record
5: oL (drive overload)
Pr5-30
7th Most Recent Fault Record
6: oL1 (electronic thermal relay 1)
Pr5-31
8th Most Recent Fault Record
7: ot1 (Over-Torque1)
Pr5-32
9th Most Recent Fault Record
8: oCn
(over-current during constant speed)
Pr5-33
10th Most Recent Fault Record
9: oCA (over-current during accel.)
Pr5-34
11th Most Recent Fault Record
10: oCd (over-current during decel.)
Pr5-35
12th Most Recent Fault Record
11: EP1 (EPROM error 1)
Pr5-36
13th Most Recent Fault Record
12: EP2 (EPROM error 2)
Pr5-37
14th Most Recent Fault Record
13: EF (external fault)
Pr5-38
15th Most Recent Fault Record
14: Ct1 (current sensor 1)
Pr5-39
16th Most Recent Fault Record
15: Ct2 (current sensor 2)
16: HPF (protection circuit fault)
17: oH1 (IGBT overheat)
18: oH2 (Heatsink overheat)
19: SoFt (Pre-charge circuit error)
20: ACI. (AI2 error)
21: ASC (RS-485 error)
22: PI.d (PID error)
23: Pu(Keypad communication overtime)
24: tunE (Auto tuning failure)
25: bF (braking chopper failure)
26: PG (PG error)
27: PHL
(Phase-Loss protect or capacitor aged)
28: CC (current signal error during stop)
29: CPu (CPU error)
30: FAn (Fan failure)
31: AnI fault (Analog input error)
32: ot2 (Over-Torque2)
33: oL2 (electronic thermal relay 2)
34: rnot (Motor selection error)
36: LUr (Low Voltage during Run)
37: oUd (over-voltage during decel)
38: `x CoPY (Parameter copy error)
39: LU (Low Voltage)
40: bb (External Base Block )
Pr5-40 Full-Load Current of Motor 2
Amp (10~120% of drive’s rated current)
##.##
Pr5-41
Auto Torque Compensation of Motor 2
0.0
25.0%
0.0
Pr5-42
Slip Compensation of Motor 2
0
20 RPM
0
Pr5-43
Number of Motor Poles 2
2
20
4
Pr5-44
Rotor Resistance R1 of Motor 2
0.000
65.535
0
Pr5-45
Motor 2- Electronic Thermal Relay
Selection (oL2)
0: Electronic thermal relay function
disabled
0
1: Inverter duty motor
(with independent cooling fan)
2: Standard motor
(with shaft mounted cooling fan)

Related product manuals