EasyManua.ls Logo

TOPTEK TOPVERT S1-211P5 - Model Specifications and Ratings; Available Models by Power Type

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOPVERT S1 Series
E-
4
1-Phase, 100 ~ 120VAC, 50/60 Hz (Tolerance Range: 90 ~ 132V, 47 ~ 63Hz) Output Voltage :200~240VAC
Model
Applicable Motor
(230V 4 P)
Rated Output Source Enclosure Construction
TOPVERT
S1-xxxxx
Power
(kW)
Horse
Power
(Hp)
Capacity
(kVA)
Current
(A)
Voltage
(V)
Frequency
(Hz)
Current
(A)
Cooling
Methods
Protection
Methods
(IP/NEMA)
Net
Weight
(kg)
Frame Code
110P2*
110P2A
0.2 0.25 0.6 1.6 6.1
110P4*
110P4A
0.4 0.5 1.2 3 11.4
110P7*
110P7A
0.75 1 2 5
3-
Phase,
0-240
(Max)
0.1- 600
19.1
Fan-
cooled
IP 20
NEMA 1
S1-A
1-Phase, 200 ~ 240VAC, 50/60 Hz (Tolerance Range: 180 ~ 264V,47 ~ 63Hz)
Model
Applicable Motor
(230V 4 P)
Rated Output Source Enclosure Construction
TOPVERT
S1-xxxxx
Power
(kW)
Horse
Power
(Hp)
Capacity
(kVA)
Current
(A)
Voltage
(V)
Frequency
(Hz)
Current
(A)
Cooling
Methods
Protection
Methods
(IP/NEMA)
Net
Weight
(kg)
Frame Code
210P4*
210P4A
0.4 0.5 1.2 3 5.7
0.92
210P7*
210P7A
0.75 1 2 5 9.5
0.92
211P5*
211P5A
1.5 2 3 7.5 14.3
1.10
S1-A
212P2*
212P2A
2.2 3 4.4 11
3-
Phase,
0-240
(Max)
0.2- 600
21
Fan-
cooled
IP 20
NEMA 1
S1-B
3-Phase, 200 ~ 240VAC, 50/60 Hz (Tolerance Range:180 ~ 264V,47 ~ 63Hz))
Model
Applicable Motor
(230V 4 P)
Rated Output Source Enclosure Construction
TOPVERT
S1-xxxxx
Power
(kW)
Horse
Power
(Hp)
Capacity
(kVA)
Current
(A)
Voltage
(V)
Frequency
(Hz)
Current
(A)
Cooling
Methods
Protection
Methods
(IP/NEMA)
Net
Weight
(kg)
Frame Code
230P4*
230P4A
0.4 0.5 1.2 3 3.3
0.93
230P7*
230P7A
0.75 1 2 5 5.5
0.93
231P5*
231P5A
1.5 2 3 7.5 8.3
1.20
S1-A
232P2*
232P2A
2.2 3 4.4 11 12.1
233P7*
233P7A
3.7 5 6.8 17
3-
Phase,
0-240
(Max)
0.1-600
18.7
Fan-
cooled
IP 20
NEMA 1
S1-B
3-Phase, 380 ~ 480VAC, 50/60 Hz (Tolerance Range: 342 ~ 528V,47 ~ 63Hz)
Model
Applicable Motor
(460V 4 P)
Rated Output Source Enclosure Construction
TOPVERT
S1-xxxxx
Power
(kW)
Horse
Power
(Hp)
Capacity
(kVA)
Current
(A)
Voltage
(V)
Frequency
(Hz)
Current
(A)
Cooling
Methods
Protection
Methods
(IP/NEMA)
Net
Weight
(kg)
Frame Code
430P4*
430P4A
0.4 0.5 1.3 1.6 1.8 0.89
430P7*
430P7
0.75 1 2.4 3 3.3 0.89
431P5*
431P5A
1.5 2 3.3 4.2 4.6 0.89
S1-A
432P2*
432P2A
2.2 3 4.8 6 6.6
433P7*
433P7A
3.7 5 6.8 8.5
3-
Phase,
0-460
(Max)
0.1-600
9.4
Fan-
cooled
IP 20
NEMA 1
S1-B
Remark: *
Not for new design