EasyManua.ls Logo

Toro 03200 - Page 11

Toro 03200
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
SET-UP INSTRUCTIONS
CHECK ANGLE INDICATOR (Fig. 8)
DANGER
To reduce risk of injury or death due to rollover
do not operate on side hills steeper than 25.
Figure 8
1
1
1. Angle indicator
1. Park machine on a flat, level surface.
2. Verify that the machine is level by placing a hand
held inclinometer (supplied with machine) on the frame
cross rail, by the tool box. The inclinometer should read
zero degrees, when viewed from the operator's
position.
3. If inclinometer does not read zero degrees, move
the machine to a location where a zero degree reading
is obtained. The angle indicator, mounted on machine,
should now read zero degrees as well.
4. If angle indicator does not read zero degrees,
loosen the two screws and nuts securing angle
indicator to mounting bracket, adjust indicator to
obtain a zero degree reading and tighten capscrews.
INSTALL HOOD LATCH (Fig. 9)
(European Compliance)
1. Unhook hood latch from bracket.
2. Slide hood lock bracket onto latch.
Figure 9
1. Hood latch
2. Hood latch bracket
3. Hood lock bracket
1
2
3
3. Re-hook latch onto bracket.
4. Insert 1/4-20 x 1-1/2" lg. capscrew thru hood
lock bracket and secure with a capscrew, flat washer
and locknut.
INSTALL EXHAUST GUARD (Fig. 10)
(European Compliance)
1. Position exhaust guard around muffler while
aligning mounting holes with holes in frame.
2. Secure exhaust guard to frame with (4) self tapping
screws.
Figure 10
1. Exhaust guard
1
INSTALL ROPS (Fig. 11)
IMPORTANT: Never weld or modify ROPS. Replace a
damaged ROPS, do not repair or revise. Any alteration
of ROPS must be approved by manufacturer.
3. Lower ROPS frame onto traction unit mounting
brackets, aligning mounting holes. Vent tube, secured
to ROPS, must be positioned on left side of machine.