Troubleshooting
Problem
PossibleCauseCorrectiveAction
Thefueltankisshowingsignsof
collapsingorthemachineisshowingsigns
offrequentlyrunningoutoffuel.
1.Theair-cleanerpaperelementclogged.
1.Cleanthepaperelement.
1.Theengineloadisexcessive.1.Reducegroundspeed.
2.Theoillevelinthecrankcaseislow.2.Addoiltothecrankcase.
3.Thecoolingnsandairpassages
undertheengineblowerhousingare
plugged.
3.Removetheobstructionfromthe
coolingnsandairpassages.
4.Theaircleanerisdirty.
4.Cleanorreplacetheair-cleaner
element.
Theengineoverheats.
5.Dirt,water,orstalefuelisinfuel
system.
5.ContactanAuthorizedServiceDealer
1.Themotion-controlleversarenotin
theNEUTRAL-LOCKposition.
1.Movethemotion-controlleverstothe
NEUTRAL-LOCKposition.
2.Theparkingbrakeisdisengaged.2.Engagetheparkingbrake.
3.Thebatteryisdead.
3.Chargethebattery.
4.Theelectricalconnectionsare
corrodedorloose.
4.Checktheelectricalconnectionsfor
goodcontact.
5.Afuseisblown.5.Replacethefuse.
Thestarterdoesnotcrank.
6.Arelayorswitchisdamaged.
6.ContactanAuthorizedServiceDealer.
1.Thefueltankisempty.1.Fillthefueltank.
2.Thechokeisnoton.
2.MovethechokelevertoOn.
3.Theaircleanerisdirty.
3.Cleanorreplacetheair-cleaner
element.
4.Thespark-plugwire(s)islooseor
disconnected.
4.Installthewire(s)onthesparkplug.
5.Thesparkplug(s)ispitted,fouled,or
thegapisincorrect.
5.Installanew,correctlygappedspark
plug(s).
6.Thereisdirtinfuellter.6.Replacethefuellter.
7.Dirt,water,orstalefuelisinfuel
system.
7.ContactanAuthorizedServiceDealer.
8.Thereisincorrectfuelinthefueltank.8.Drainthetankandreplacethefuelwith
thepropertype.
Theenginedoesnotstart,startshard,or
failstokeeprunning.
9.Theoillevelinthecrankcaseislow.9.Addoiltothecrankcase.
1.Theengineloadisexcessive.1.Reducegroundspeed.
2.Theaircleanerisdirty.
2.Cleantheair-cleanerelement.
3.Theoillevelinthecrankcaseislow.3.Addoiltothecrankcase.
4.Thecoolingnsandairpassages
undertheengineblowerhousingare
plugged.
4.Removetheobstructionfromthe
coolingnsandairpassages.
5.Thesparkplug(s)ispitted,fouled,or
thegapisincorrect.
5.Installanew,correctlygappedspark
plug(s).
6.Thefueltankventisblocked.6.ContactanAuthorizedServiceDealer.
7.Thereisdirtinthefuellter.7.Replacethefuellter.
8.Dirt,water,orstalefuelisinthefuel
system.
8.ContactanAuthorizedServiceDealer.
Theenginelosespower.
9.Thereisincorrectfuelinthefueltank.9.Drainthetankandreplacethefuelwith
thepropertype.