8
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
8. SELF DIAGNOSTIC FUNCTION
1) Press 9 button on Remote Control during display of adjustment menu in the service mode.
The diagnosis will begin to check if interface among ICs are executed properly.
2) During diagnosis, the following displays are shown.
23******
POWER : 00
BUS LINE : OK
BUS CONT : OK
BLOCK : UV V1 V2
<SELF CHECK>
Part number of microprocessor (Q100)
Operation number of protecting circuit ----00 is nor-
mal.
When indication is other than 00, overcurrent apts to
flow, and circuit parts may possibly be damaged.
BUS LINE CHECK ----OK is normal.
SDA1-GND ------------- SDA-GND short circuit.
SCL1-GND -------------- SCL-GND short circuit.
SCL1-SDA1 ------------- SCL-SDA short circuit.
BUS CONT ----OK is normal.
When indication shows Q uuu NG, the device with
the number may possibly be damaged.
BLOCK
UV : TV reception mode
V1 : VIDEO 1 input mode (a1)
V2 : VIDEO 2 input mode (a2)
Indicated color of mode now selected : Green and Red
Indicated color of other modes : White
Green : Normal
Red : The microprocessor operates to provide judgement
of no video signal. The red color is still indicated
though the signal is input, failure may exist in input
signal line.
*
The items marked with are not usable to display in the SELF DIAGNOSTIC FUNCTION for some model.