GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
CHAPTER 2 SPECIFIC INFORMATIONS
Table-1
SAFETY INSTRUCTIONS
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
RCUT
GCUT
BCUT
GDRV
BDRV
SCNT
BRTC
COLC
TNTC
SAVC
ATT
STVC
STRF
SPEC
40H
40H
40H
40H
40H
0AH
40H
3AH
44H
20H
20H
20H
20H
20H
Item Name of adjustment Preset
Data
R CUTOFF
G CUTOFF
B CUTOFF
G DRIVE
B DRIVE
SUB-CONTRAST
SUB-BRIGHT
SUB-COLOR
SUB-TINT
SAP VCO
ATTENUATOR
STEREO VCO
STEREO FILTER
SPECTRAL
Item Name of adjustment Preset
WBAN
HPOS
VPOS
HIT
LIN
VSC
WID
DPC
CNR
TRAP
VPS
VCP
HCP
VFC
STEREO SEPARATION
HORIZ. POSITION
VERT. POSITION
HEIGHT
V-LINEARITY
V-S CORRECTION
PICTURE WIDTH
E-W PARABOLA (DPC)
E-W CORNER
TRAPEZIUM
V-SHIFT
V-COMPENSATION
H-COMPENSATION
V-F CORRECTION
20H
16H
03H
26H
07H
02H
35H
17H
09H
08H
01H
03H
00H
0FH
16H
19H
1CH
03H
25H
13H
03H
07H
09H
43H
3DH
48H
25H
0FH
21H
21H
1DH
Table-2
DESIGN MODE
ADJUSTING ITEMS AND DATAS IN THE DESIGN MODE:
Item Name of adjustment Preset Data Data Remarks
Table-3
CIRCUIT CHECKS
Table-4
Data
OPT0 OPTION0 20H 20H
OPT1 OPTION1 84H 84H
OPT2 OPTION2 01H 01H
36"
HIGH VOLTAGE AT ZERO BEAM: (A) 32.0kV
MAX HIGH VOLTAGE:
(B) 34.0kV
FBT DETECTION VOLTAGE (C) 22.3 V