– 15 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
1
2
36ZP18P
32ZP18P
36ZP18P
32ZP18P
Focus adjustment (1)
FOCUS VR
Focus adjustment (2)
R950
Adjustment of vertical position
Conditions:
PAL Retoma signal, User Adjustment Standard
Adjustment:
Use the focus volume of the focus block (T461), and set it to the most counterclockwise position
where the lateral fly-back lines of the screen center become minimized.
Conditions:
PAL Retoma signal
WIDE mode, User adjustment standard
Adjustment:
Use the sub-focus volume (R950) on the CRT-drive printed circuit board, and set it to the position
where the longitudinal fly-back lines of the corner area become minimized.
Repeat Items 1 and 2 above for adjustment to optimize the entire screen.
Conditions:
PAL WG Philips Pattern
WIDE mode, User Adjustment Standard
Adjustment:
Use [VPS1] and adjust so that the top and bottom positions will contact the mask.
(Adjust with the direction of CPT either facing south or north. If it is impossible to do so, offset the
difference.)
No. Target model names Adjusting items Adjusting methods
2. Circuit adjustment (Volume/data adjustment)