Factory preset data will be loaded after setting Model ID data.
(Refer to Initialization of Memory Data of QA02 and setting data of signal board.)
Adjusting the Data
Pressing of VOLUME +/- button will change the value of data in the range from 00H to
FFH. The variable range depends on the adjusting item.
I2C Bus Off
Turn off I2C communication between IC700 and IC400.
1) Press and hold the CALL button on the remote control, then press the Volume
+ button on the TV.
2) Display "BUS Off" OSD.
3) I2C communication turned off.
Note:
OPT2 TV SET OPTION 2
OPT3 TV SET OPTION 3
OPT4 TV SET OPTION 4 (PANEL OPT DATA FOR VENDOR)
OPT5 TV SET OPTION 5 (PANEL OPT DATA FOR SIZE)
OPT6 TV SET OPTION 6 (HOTEL MODE)
OPT7 TV SET OPTION 7 (HOTEL MODE)
OPT8 TV SET OPTION 8 (HOTEL MODE)
TVOP TV SET OPTION
ID MODEL ID
BDWID BORDER WIDTH FOR EXACT SCAN
BDHIT BORDER HEIGHT FOR EXACT SCAN