5
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO181/211
TROUBLESHOOTING
5 - 19
5.1.10 Service call for others
[C94] Firmware update error
A C94 error message appears when either of the following Main PC boards is installed to e-
STUDIO181/211.
- The Main PC board for e-STUDIO163/203 in which e-STUDIO166/206 firmware is installed
- The Main PC board for e-STUDIO163/166/203/206 in which e-STUDIO181/211 firmware is installed
Be sure not to make a mistake in the combination of the Main PC board and the firmware since the
error message does not appear if there is an incorrect combination. Each equipment condition
according to the combination of the Main PC board and the firmware is as shown in the list below.
Fig. 5-1
Note:
Be sure to check the version of the firmware after it is updated.
Main PC board
Start-up
disabled
Start-up
disabled
Start-up
disabled
Start-up
disabled
Start-up
disabled
Start-up
disabled
Start-up
disabled
Start-up
disabled
Start-up
disabled
C94
C94
C94
e-STUDIO165/205
e-STUDIO163/203
e-STUDIO167/207/237
e-STUDIO166/206
e-STUDIO182/212/242
e-STUDIO181/211
e-STUDIO
165/205
e-STUDIO
163/203
e-STUDIO
166/206
e-STUDIO
182/212/242
e-STUDIO
181/211
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Firmware
167/207/237
e-STUDIO
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
Installation
disabled
C94 error message appearsC94
Start-up enabled (function restricted)
It is possible to start up the equipment normally
It is NOT possible to start up the equipment
It is NOT possible to install the Main PC board in the
equipment
Start-up enabled
Start-up disabled
Installation disabled
It is possible to start up the equipment even if its copy
speed becomes slow
Start-up
enabled
(function
restricted)
Start-up
enabled
(function
restricted)
Start-up
enabled
(function
restricted)
Start-up
enabled
(function
restricted)
Start-up
enabled
(function
restricted)
Start-up
enabled