TROUBLESHOOTING
5 - 22
5.2 Troubleshooting for the Image
1. Abnormality of image density / Gray balance
Fig. 5-2
Defective area Step Check items Prescription
Density/Gray balance 1 Check the density/gray balance. Adjust the density.
Printer section 2 Check test print image (07-113). Go to step 4 if there is any problem
on image.
Scanner 3 Are the original glass and CIS unit
dirty?
Clean them.
Printed image 4 Is the image faded? Perform troubleshooting for faded
image.
5 Is background fogging occurring? Perform troubleshooting for
background fogging.
6 Is there a blotch on the image? Perform troubleshooting for blotched
image.
7 Is the image transferred normally? Perform troubleshooting for
abnormal transfer.
Feeding direction
Image density Gray balance