2
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO181/211
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 7
[INTER
RUPT]
LED
Number
[Digital
keys]
Display
position
of the
density
LED
Items to check ON/Blinking OFF
ON [1]
0- --
1- --
2- --
3- --
4- --
5 High-voltage transformer error Normal Error
6- --
ON [2]
0- --
1- --
2- --
3- --
4 CIS home position sensor Home position Other than
home position
5 Platen sensor Cover opened Cover closed
6 ADF connection Connected Not connected
ON [4]
0 ADF read sensor Original
present
No original
1- --
2 ADF exit sensor Original
present
No original
3 ADF opening/closing sensor ADF opened ADF closed
4 ADF cover opening/closing sensor Cover opened Cover closed
5 ADF empty sensor Original
present
No original
6 ADF tray sensor Original
present
No original
ON [5]
0- --
1- --
2- --
3 ADF original width sensor-2 Original
present
No original
4 ADF original width sensor-1 Original
present
No original
5 ADF original length sensor Original
present
No original
6 ADF registration sensor Original
present
No original