ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 35
Notes:
• The digit after the hyphen in “Code” of the following table is a sub code.
• In “RAM”, the SRAM of the board in which the data of each code is stored is indicated. “M”
and “SYS” stands for the MAIN board.
Setting mode (08)
Code
Classific
ation
Items
Funct
ion
Default
<Accept
able
value>
RAM Contents
Proce
dure
202 User
interface
Counter installed externally ALL 0
<0-3>
M 0: No external counter
1: Coin controller
2: Copy key card
3: Key copy counter
1
203 General Line adjustment mode ALL 0
<0-1>
M 0: For factory shipment
1: For line
* Field: “0” must be
selected
1
204 User
interface
Auto-clear timer setting ALL 3
<0-15>
SYS 0: Invalid 1: 15 sec.
2: 30 sec. 3: 45 sec.
4: 60sec. 5: 75 sec.
6: 90 sec. 7: 105 sec.
8: 120 sec.9: 135 sec.
10: 150 sec.
11: 180 sec.
12: 210 sec.
13: 240 sec.
14: 270 sec.
15: 300 sec.
1
205 User
interface
Auto power save mode
timer setting
ALL 8
<0-30>
SYS 0: Invalid 2:1 min.
4: 2 min. 6:3 min.
7: 4 min. 8:5 min.
10: 10 min. 11:15 min.
12: 20 min. 13:25 min.
14: 30 min. 15:35 min.
16: 40 min. 17:45 min.
18: 50 min. 19:55 min.
20: 60 min. 21:70 min.
22: 80 min. 23:90 min.
24: 100 min.25:110 min.
26: 120 min.
27: 150 min.
28: 180 min.
29: 210 min.
30: 240 min.
1
206 User
interface
Auto Shut Off Mode timer
setting (Auto Sleep Mode)
ALL 24
<0-24>
M 0: 3 min. 1:5 min.
2: 10 min. 3:15 min.
4: 20 min. 5:25 min.
6: 30 min. 7:35 min.
8: 40 min. 9:45 min.
10: 50 min. 11:55 min.
12: 60 min. 13:70 min.
14: 80 min. 15:90 min.
16: 100 min.17:110 min.
18: 120 min.
19: 150 min.
20: 180 min.
21: 210 min.
22: 240 min.
23: Invalid
24: 1 min.
1