ADJUSTMENT
3 - 2
(5) After a short time, the value on the 7-segment LED becomes stable and all the “density LEDs”
are turned off.
(6) Check if the value on the 7-segment LED is within the range of 232 to 248 (i.e. the output voltage
range of the auto-toner sensor is 2.32 V to 2.48 V.).
(7) If the value is not within the range of 232 to 248, press the reproduction ratio buttons ([25%] /
[200%]) to adjust the value manually.
(8) Press the [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed on the 7-segment LED.
Fig. 3-4
(9) Turn the power OFF.
(10) Install the toner cartridge.