ADJUSTMENT
3 - 11
3.2.4 Scanner related adjustment
[A] Reproduction ratio adjustment of the primary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON (Adjustment Mode)
(2) Place a ruler on the original glass (along the direction from the rear to the front of the equipment).
(3) Press [0] and [9] simultaneously to enter the normal mode.
(4) Make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment.
(5) Press [0] and [5] simultaneously to enter the adjustment mode.
(6) Measure the distance A from 10 mm to 270 mm of the copied image of the ruler.
(7) Check if the distance A is within the range of 260±0.5 mm.
(8) If not, use the following procedure to change values and repeat the steps (3) to (7) above.
(Adjustment Mode) (Key in the code [405]) [START]
(Key in a value (acceptable values: 0 to 255))
Press the [INTERRUPT] button (stored in memory). (“AJ” is displayed.)
*The larger the adjustment value is, the higher the reproduction ratio and the longer the distance
A become (approx. 0.125 mm/step).
Fig. 3-8
50 100 150 200 250
A
Feeding direction
Copied image of the ruler