15
No.
Inspection item
Inspection result
Correspondence
17
NG <DF
*
1>
[C280]
*
2
Refer to C280 Troubleshoot of service
manual and check each item.
NG <DF
*
1>
[C290]
*
2
Step 1.
Check if 24V supplied to the SYS
board.
If supplied, replace the SYS board.
Step 2
. Check 24V (CN125) and SG on.
Confirm if the SYS board is short circuited
If shorted, go to
Step 3
If not shorted, go to Step 4.
Step 3
. Check if the power supply is short
circuited as in Step 2 by pulling
disconnecting the supply harness (CN125)
on the SYS board.
If shorted, replace the
SYS board
.
If not shorted, go to Step 4.
Step 4. Check if the fuse
(F203)
on the
LVPS
is open circuited.
If open, replace the LPVS.
If not open, go to Step 5.
Step 5.
Check and replace power supply
Harness
Step 6.
Replace LVPS and SYS board in
order.
NG <DF*1>
[C550] *2
Refer to C550 Troubleshoot of service
manual and check each item.
NG <DF*1>
[C551] *2
Refer to C551 Troubleshooting in the
service manual and check each item.
NG <DF*1>
[C552] *2
Refer to C552 Troubleshooting in the
service manual and check each item.
NG <DF*1>
[C553] *2
Refer to C553 Troubleshooting in the service
manual and check each item.
NG <DF*1>
[C554] *2
Refer to C554 Troubleshooting in the service
manual and check each item.
NG <DF*1>
[F110]/[F111] *2
Step 1
. Update scanner firmware.
Step 2
. Replace the SYS board.
NG <DF*1>
[F350] *2
Replace the SYS board.
(Continued on next page)
SLG
Communication
*1Here shows
the installed
status of the DF
(No
ADF, RADF,
DSDF
*2Although it
may be
displayed as
"WARMUP", it is
reference
information.