Hydro Unit
Installation Manual
– 12 –
Control line
TB03
TB03 TB02
TB01
TB04
▼Fig.7-19
Input power
220-240V~
50Hz
Input power
380-415V
3N~50Hz
Input power
220-240V~50Hz
Backup heater power
supply
Hot water cylinder power
supply
Hot water
cylinder
to Outdoor
Unit
to Second remote
controller
1
2
3
4
1
2
3
4
5
6
A
B
7
8
9
10
1
3
4
6
2
3
5
6
CN23
CN20
CN22
8
9
10
7
8
9
10
CN22
CN22
CW
CCW
N
▼Fig.7-18
Mixing-Valve
type 2 for 2 zone
control
Mixing-Valve type 1
for 2 zone control
Max 12 m
230 V 100 mA
0.75 mm² or more
Temp sensor in hot
water cylinder
Max 5 m shielded wire
0.75 mm² or more
Max 5 m shielded
wire 0.75 mm² or
more
Max 12 m non
voltage 0.75 mm² or
more
Compressor
operation output
(local)
Defrost output
(local)
Boiler operation
(local)
Alert output
(local)
3Way-Valve for hot
water cylinder
Booster heater
(local)
2Way-Valve for
cooling stop
Max 12 m
230 V 1 A
0.75 mm² or more
Pump (local)
Max 12 m
230 V 100 mA
0.75 mm² or more
Max 12 m
230 V 1 A
0.75 mm² or more
Temp sensor for
2 zone control
23-EN
24-EN
Electrical installation
WARNING
Ensure electrical circuits are isolated before
commencing the electrical installation.
The electrical installation must be completed by a
qualified electrician.
The electrical installation must comply to all Local,
National and International electrical installation
regulations.
This product must be earthed in accordance with
Local, National and International electrical installation
regulations.
CAUTION
The Hydro Unit must be connected to a dedicated
power supply for the back up heater circuit.
The electrical supply must be protected by a suitably
sized over current protection device (fuse, MCB etc)
and an earth leakage protection device.
The Hydro Unit must be connected to the mains power
supply using a isolating switch which disconnects all
poles and has a contact separation of at least 3 mm.
The cord clamps, attached to the Hydro Unit, must be
used to secure the electrical cables.
Wrong connection of electrical cables may result in
electrical component failure or fire.
Ensure the electrical cables are sized in accordance
with the installation instructions.
Check that cabling will not be subject to wear,
corrosion, excessive pressure, vibration, sharp edges
or any other adverse environmental effects.
The check shall also take into account the effects
of aging or continual vibration from sources such as
compressor or fans.
The earth wire should be longer than the power
supply wire from the strain relief clamp. This ensures
that if the cable is pulled out of the terminal block,
the power supply wires are disconnected first.
Input power
220-240V~50Hz
Backup heater power
supply
Hot water cylinder power
supply
Single phase 6kW Back up heater type only
Input power
220-240V~
50Hz
Hot water
cylinder
to Outdoor
Unit
to Second remote
controller