R410A
FILE NO. SVM-15032
SERVICE MANUAL
AIR-CONDITIONER
MULTI TYPE
MMD-AP0186HP-E
MMD-AP0246HP-E
MMD-AP0276HP-E
MMD-AP0366HP-E
MMD-AP0486HP-E
MMD-AP0566HP-E
INDOOR UNIT
< Concealed Duct High Static Pressure Type >
MMD-AP0186HP-TR
MMD-AP0246HP-TR
MMD-AP0276HP-TR
MMD-AP0366HP-TR
MMD-AP0486HP-TR
MMD-AP0566HP-TR

Other manuals for Toshiba MMD-AP0186HP-E

Questions and Answers

  • M
    Mary EsparzaAug 10, 2025
    Why won't my Toshiba MMD-AP0186HP-E compressor start?
    • J
      jacob80Aug 11, 2025
      The compressor might not start due to several reasons: * It could be within the 3-minute delay period after a compressor shutdown. If so, check if the compressor is in this delay period. * The air conditioner might have gone thermo OFF. Verify the thermo OFF status. * The system might be operating in fan mode or the timer is set. Check if the air conditioner is in fan mode or if the timer is active. * The system could be undergoing initial communication. Allow time for the system to complete this process.
  • J
    Jose AguilarAug 17, 2025
    Why won't the compressor start on my Toshiba MMD-AP0186HP-E?
    • E
      Edward WilliamsAug 17, 2025
      If the compressor of your Toshiba Air Conditioner won't start, consider these possibilities: * It might be within the 3-minute delay period after a compressor shutdown. * The air conditioner might have thermo OFF. * It could be operating in fan mode or set on a timer. * The system might be undergoing initial communication.
  • S
    Steven JenningsAug 22, 2025
    Why won't the indoor fan stop on my Toshiba MMD-AP0186HP-E?
    • H
      heathercarrollAug 22, 2025
      If the indoor fan of your Toshiba Air Conditioner won't stop, it might be performing the elimination of residual heat as part of the air conditioner shutdown process after heating operation.
  • A
    Amy PorterAug 28, 2025
    Why won't the indoor fan start on my Toshiba MMD-AP0186HP-E Air Conditioner?
    • X
      xgrossAug 28, 2025
      If the indoor fan of your Toshiba Air Conditioner won't start, it could be due to cold air discharge prevention control, which is a part of the heating process.
  • M
    Mark BarnesSep 4, 2025
    Why does the outdoor fan on my Toshiba Air Conditioner not start or change speed?
    • C
      Caleb BarnesSep 4, 2025
      If the outdoor fan of your Toshiba Air Conditioner doesn't start or changes speed unexpectedly, it might be due to cooling operation under low outside temperature conditions or during a defrosting operation.

Toshiba MMD-AP0186HP-E Specifications

General IconGeneral
RefrigerantR32
Indoor Unit Weight10 kg
Cooling Capacity (kW)5.0 kW
Power Supply220-240V, 50Hz
Cooling Capacity5.0 kW
Heating Capacity5.6 kW
Noise Level (Outdoor)52 dB