What does it mean if my Toshiba MMK-UP0361HP-E displays an indoor unit TC1 sensor trouble?
- AAnthony HartAug 25, 2025
If the Toshiba Air Conditioner detects an issue with the indoor unit TC1 sensor, the suggested solution is F03.
What does it mean if my Toshiba MMK-UP0361HP-E displays an indoor unit TC1 sensor trouble?
If the Toshiba Air Conditioner detects an issue with the indoor unit TC1 sensor, the suggested solution is F03.
What does it mean if my Toshiba Air Conditioner displays Comp. 2 case thermostat operation?
If your Toshiba Air Conditioner displays a 'Comp. 2 case thermostat operation', the suggested solution is H14.
What does it mean if my Toshiba Air Conditioner displays TD2 sensor miswiring?
If your Toshiba Air Conditioner displays a 'TD2 sensor miswiring', the suggested solution is H15.
What does it mean if my Toshiba MMK-UP0361HP-E displays Oil level detective circuit trouble?
If your Toshiba Air Conditioner displays a 'Oil level detective circuit trouble', the suggested solution is H16.
What does it mean if my Toshiba Air Conditioner displays Compressor trouble Step out?
If your Toshiba Air Conditioner displays a 'Compressor trouble (Step out)', the suggested solution is H17.
What does it mean if my Toshiba MMK-UP0361HP-E displays TD3 sensor miswiring?
If your Toshiba Air Conditioner displays a 'TD3 sensor miswiring', the suggested solution is H25.
What does it mean if my Toshiba MMK-UP0361HP-E displays indoor unit centre unit duplicated?
If your Toshiba Air Conditioner displays a message indicating duplicated indoor unit centre unit, the suggested solution is L03.
What does it mean if my Toshiba Air Conditioner displays outdoor unit line address duplicated?
If your Toshiba Air Conditioner displays a message indicating outdoor unit line address duplicated, the suggested solution is L04.
What does it mean if my Toshiba Air Conditioner displays duplicated indoor units with priority?
If your Toshiba Air Conditioner displays a message indicating duplicated indoor units with priority on the indoor unit with priority, the suggested solution is L05.
Category | Air Conditioner |
---|---|
Cooling Capacity | 3.6 kW |
Power Supply | 220-240 V, 50 Hz |
Refrigerant | R410A |
Indoor Unit Weight | 9 kg |
Outdoor Unit Dimensions (WxHxD) | 780x540x260 mm |
Covers the remote's signal emitter, basic controls like Start/Stop, mode selection, and display.
How to operate the air conditioner for cooling, heating, and fan-only functions.
Instructions for using the air conditioner's dry mode for dehumidification.
Details on using the automatic operation mode for multi-system compatibility.
Instructions for setting the ON and OFF timers for scheduled air conditioner operation.
How to activate High Power mode for rapid cooling or heating.
Adjusting the vertical airflow direction using the remote controller's FIX button.
How to operate the unit temporarily using the reset button when the remote is lost.
Step-by-step guide for cleaning the air filters to maintain performance.
Common checks to perform before requesting professional service for the air conditioner.
Diagnosing and resolving problems related to poor cooling or heating performance.
Technical specifications including model numbers, sound levels, and weight.