Do you have a question about the Toshiba MMU-AP0121YH and is the answer not in the manual?
Category | Air Conditioner |
---|---|
Cooling Capacity (kW) | 3.5 |
Heating Capacity (kW) | 4.0 |
Power Supply | 220-240V, 50Hz |
Refrigerant | R410A |
Indoor Unit Weight | 9 kg |
Outdoor Unit Noise Level | 50 dB |
Important warnings regarding the safe installation of the air conditioner.
Guidelines for safe and proper usage of the air conditioner.
Safety precautions for moving or repairing the air conditioner.
Specific checks for proper installation methods and fixing.
Detailed identification of parts for various indoor unit types.
List of remote controllers and related accessories sold separately.
Identification of parts for concealed duct and high static pressure indoor units.
Identification of parts for slim duct and under ceiling indoor units.
Identification of parts for high wall indoor units.
Identification of parts for floor standing cabinet, concealed, and standard types.
Identification of components of the outdoor unit.
Explanation of the various indicators and displays on the remote controller.
Identification and function of the buttons on the remote controller.
Controls for air volume selection and timer settings.
Controls for fan operation, filter reset, and air direction swing.
Controls for power, operation mode, and temperature adjustment.
Steps to prepare the unit and essential operating requirements.
How to select operation mode and adjust air volume.
How to set temperature and procedure to stop the unit.
How to set the louver for optimal cooling airflow.
Specific instructions for adjusting wind direction on 4-way cassette units.
Steps to adjust air direction and enable/disable swing function.
Controls for selecting individual indoor units for direction settings.
Specific instructions for 2-way cassette unit air direction.
Specific instructions for 1-way cassette unit air direction.
Steps to adjust air direction and enable/disable swing function.
Controls for selecting individual indoor units for direction settings.
How to adjust vertical and horizontal air direction for high wall units.
How to set air direction and activate swing function.
Procedure to change the direction of the air outlet port.
How to adjust vertical and horizontal air direction for floor standing units.
Notes on air direction adjustment and flap operation.
Explanation of timer types: OFF, Repeat OFF, and ON timer.
How to cancel an active timer setting.
Guidelines for selecting a suitable installation location for the unit.
Instructions and warnings for electrical wiring and connections.
Instructions on how to clean and reset the air filter indicator.
Procedure for removing and attaching air filters for various unit types.
Procedure for removing and attaching air filters for floor standing units.
Steps to properly reinstall the air filter after cleaning.
Detailed instructions for cleaning the air inlet grille.
How to clean the main unit and remote controller safely.
Steps for preparing the unit for storage and checks before operation.
Tips for maintaining optimal room temperature and clean air filters.
Advice on managing indoor temperature and using curtains.
Adjusting airflow for even room air circulation.
Essential checks and factors affecting heating capacity.
Explanation of defrost cycle, protection features, and fan rotation.
Explanation of protective devices and performance during cooling/heating.
Recommended temperature and humidity ranges for cooling and heating modes.
Critical warnings about improper re-installation and unsuitable installation locations.
Precautions to minimize noise and vibration issues.
Common sounds/smells and their causes, not indicating failure.
Troubleshooting steps for automatic operation changes and unit failure to operate.
Troubleshooting steps for insufficient cooling/heating and other operational problems.
Procedure to check the stored trouble history of the air conditioner.
List of accessory parts provided with the unit.
Explanation of warning and caution symbols used in the manual.
Critical warnings for safe installation and handling.
Cautions for safe installation and handling.
Essential tools and safety precautions for R410A refrigerant installation.
Guidelines for selecting and using piping materials for R410A.
Caution regarding installation locations where combustible gas may leak.
Recommended clearance and space requirements for installation.
Table showing combinations of outdoor units based on HP.
Instructions for safely carrying and handling the outdoor unit.
Ensuring proper drainage and a stable foundation to prevent noise and vibration.
Measures to protect the outdoor unit from snow accumulation.
Correct method for placing stools and mounting vibration-proof rubber.
Guidelines for connecting multiple outdoor units in a system.
Steps for connecting refrigerant pipes and requirements for brazing.
Examples of connecting pipes using attached and locally procured parts.
Tables showing flare machining margins for rigid and imperial fittings.
Specifications for brazed pipe connections, including dimensions and tolerances.
Guidance on selecting appropriate pipe materials and understanding capacity codes.
Tables detailing pipe sizes for various unit combinations and capacities.
Guidance on selecting appropriate branching joints and headers.
Information on selecting Flow Selector units based on capacity.
Recommended minimum wall thickness for copper pipes used with R410A.
Maximum permissible lengths and height differences for refrigerant pipes.
System limitations regarding the number and capacity of connected units.
Procedures for airtight testing, air purging, and opening valves.
Methods for checking refrigerant gas leaks.
Proper heat insulation for refrigerant pipes to prevent condensation.
Calculation and procedure for adding refrigerant.
Method for charging refrigerant, including liquid and gas methods.
Instructions on how to fully open various valves.
Applying heat insulation to pipes to prevent dew and water leaks.
Explanation of warning and caution symbols used in the manual.
Critical warnings for safe installation and handling.
Cautions for safe installation and handling.
Warnings and cautions regarding electrical work safety and regulations.
Requirements for proper electrical wiring and connection methods.
Specifications for power supply to the outdoor unit.
Design considerations for electrical wiring of the system.
Power supply wiring for combined outdoor unit configurations.
Table relating unit capacities to power supply wire sizes and fuses.
Specifications for control wires between units.
How to set up group control for multiple indoor units.
Power supply wiring for indoor units when connected to an outdoor unit.
Details on connecting control wires and shield wires.
Wiring for group control of multiple units via remote controller.
Power supply specifications for indoor units and connection to FS units.
Wiring diagram for group control of indoor units connected to a FS unit.
How to connect power and control wires to the outdoor unit.
Connecting power supply wires, earthing wire, and control wires.
Procedures for automatic address setup for indoor units.
First step of automatic address setup from the outdoor unit interface.
Diagram and explanation of the header unit's P.C. board for setup.
Second step for automatic address setup, especially with central control.
Table showing DIP switch settings for line address configuration.
Manual setup procedures using switches on the outdoor unit's P.C. board.
Caution regarding relay connector connection during address setup.
How to set indoor unit addresses using the wired remote controller.
Step-by-step guide for manual address setup from the remote controller.
How to check indoor unit addresses and their positions via the remote controller.
Procedure to check unit numbers in a group control configuration.
How to confirm unit numbers in a refrigerant line using any wired remote controller.
How to change the address of an indoor unit using the remote controller.
How to change all indoor unit addresses from a remote controller.
Clearing addresses individually using a wired remote controller.
Clearing addresses from the header unit for a refrigerant line.
Important notes and incorrect connection examples for multi-unit systems.
Procedure to set the Item code for multi-unit systems.
Step-by-step guide to set an indoor unit to Cooling Only mode.
Pre-operation checks and procedure for test operation using the wired remote controller.
Performing test operations on individual units via the outdoor unit's P.C. board.
Performing individual test operations using switches on the outdoor unit's P.C. board.
Performing collective test operations for all connected units via the outdoor unit's P.C. board.
How to interpret segment displays and check codes for diagnosing outdoor unit issues.
A table listing outdoor unit check codes and their meanings.
More check codes for outdoor unit issues and their corresponding descriptions.
List of accessory parts provided with the unit.
Important cautions regarding the installation of new refrigerant air conditioners.
Critical warnings for safe installation and handling.
Cautions for safe installation and handling.
Essential tools and safety precautions for R410A refrigerant installation.
Guidance on selecting and using piping materials for R410A.
Caution regarding installation locations where combustible gas may leak.
Recommended clearance and space requirements for installation.
Visual representation of the Flow Selector unit's external dimensions and ports.
Steps for installing hanging bolts for unit mounting.
Considerations for ceiling structure and bolt installation procedures.
Steps to attach the Flow Selector unit using hanging bolts.
Limits on pipe length and height difference for system performance.
Specifications for piping materials and connection dimensions.
Pipe size specifications for indoor and multi-unit connections.
Procedures for airtight testing, air purging, and opening valves.
Methods for checking refrigerant gas leaks.
Proper heat insulation for refrigerant pipes to prevent condensation.
Warnings and cautions regarding electrical work safety and regulations.
Requirements for proper electrical wiring and connection methods.
Wiring diagram showing connections between Flow Selector unit and indoor unit.
Wiring connections for various indoor unit types.
Wiring details for 2-way cassette and 1-way cassette/floor standing units.
Wiring details for 1-way cassette and concealed duct units.
Wiring details for 1-way cassette and concealed duct units.
Wiring details for concealed slim duct and high static pressure units.
Wiring details for under ceiling, 1-way cassette, and high wall units.
Wiring details for high wall and floor standing cabinet units.
Wiring details for floor standing concealed indoor units.
Important notes and incorrect connection examples for multi-unit systems.
Procedure to set the Item code for multi-unit systems.
Requirements for ensuring refrigerant concentration limits are not exceeded in installation rooms.
Notes on refrigerant volume and room size related to concentration.