OWNERS MANUAL
MANUEL DU PROPRIETAIRE
BETRIEBSANLEITUNG
MANUALE DEL PROPRIETARIO
MANUAL DEL PROPIETARIO
MANUAL DO UTILIZADOR
GEBRUIKSAANWIJZING
ÏÄÇÃÉÅÓ ×ÑÇÓÇÓ
Indoor Unit
4-way Air Discharge Cassette Type
MMU-AP0071MH, AP0091MH, AP0121MH, AP0151MH, AP0181MH,
MMU-AP0091H, AP0121H, AP0151H, AP0181H, AP0241H,
MMU-AP0271H, AP0301H, AP0361H, AP0481H
2-way Air Discharge Cassette Type
MMU-AP0071WH, AP0091WH, AP0121WH,
MMU-AP0151WH, AP0181WH, AP0241WH,
MMU-AP0271WH, AP0301WH
1-way Air Discharge Cassette Type
MMU-AP0071YH, AP0091YH, AP0121YH,
MMU-AP0152SH, AP0182SH, AP0242SH
Concealed Duct Standard Type
MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH,
MMD-AP0241BH, AP0271BH, AP0301BH, AP0361BH, AP0481BH
Slim Duct Type
MMD-AP0071SPH(SH), AP0091SPH(SH), AP0121SPH(SH),
MMD-AP0151SPH(SH), AP0181SPH(SH)
Concealed Duct High Static Pressure Type
MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
Under Ceiling Type
MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
High Wall Type
MMK-AP0071H, AP0072H, AP0091H, AP0092H, AP0121H,
MMK-AP0122H, AP0151H, AP0181H, AP0241H
Floor Standing Cabinet Type
MML-AP0071H, AP0091H, AP0121H,
MML-AP0151H, AP0181H, AP0241H
Floor Standing Concealed Type
MML-AP0071BH, AP0091BH, AP0121BH,
MML-AP0151BH, AP0181BH, AP0241BH
Floor Standing Type
MMF-AP0151H, AP0181H, AP0241H,
MMF-AP0271H, AP0361H, AP0481H
Outdoor Unit
Heat Pump Model
MCY-MAP0401HT, HT2D,
MCY-MAP0501HT, HT2D,
MCY-MAP0601HT, HT2D

Table of Contents

Other manuals for Toshiba MMU-AP0121MH

Questions and Answers:

Toshiba MMU-AP0121MH Specifications

General IconGeneral
CategoryAir Conditioner
Cooling Capacity12000 BTU/h
Heating Capacity4.0 kW
Power SourceElectric
Energy Efficiency Ratio (EER)3.21
RefrigerantR410A
Indoor Unit Dimensions (W x H x D)798 x 293 x 230 mm
Indoor Unit Weight9 kg
TypeSplit System
Power Supply220-240V / 50Hz
Outdoor Unit Noise Level50 dB
Outdoor Unit Dimensions (W x H x D)780 x 540 x 269 mm

Summary

Safety Precautions

Installation, Use, and Repair Warnings

Covers risks of improper installation, usage, and modification of the unit.

Installation and Operational Cautions

Ensures correct installation, earthing, and safe operation practices.

Name of Each Part

Outdoor Unit Components

Identifies the air inlet, outlet, and other parts of the outdoor unit.

Indoor Unit Types and Components

Details parts for various indoor units: cassette, concealed duct, slim duct, etc.

Adjustment of Wind Direction

Heating Operation Airflow Direction

Set the air outlet flap downwards for heating to ensure even temperature.

Cooling/Dry Operation Airflow Direction

Set the air outlet flap upwards for cooling to diffuse cold air evenly.

Adjusting Airflow Using Swing Function

How to use the swing function to automatically change air direction.

Stopping Airflow Swing

Procedure to stop the horizontal flap from swinging at a desired position.

Correct Usage

Preparation and Requirements

Turn on power supply, understand operational requirements before use.

Operation Steps

Guide on how to start operation, select mode, air volume, and set temperature.

Stop Operation

Procedure for stopping the air conditioner unit.

Timer Operation

Timer Operation Types

Explains OFF timer, repeat OFF timer, and ON timer functions.

Setting the Timer

Steps to set timer type, time, and confirm settings.

Cancel Timer Operation

How to cancel the timer operation.

Installation

Installation Location

Guidelines for selecting a safe and suitable location for unit installation.

Electric Wiring

Instructions on proper earthing and circuit breaker installation.

Maintenance

Cleaning the Air Filter

Instructions on checking, cleaning, and resetting the air filter.

Daily Maintenance

Recommends qualified service personnel for daily maintenance, especially for certain models.

Air Conditioner Operations and Performance

Check Before Operation

Checks for correct earth wire, air filter installation before operating.

Heating Capacity (Heat-pump Model)

Explains heating operation principles and factors affecting capacity.

Defrost Operation (Heat-pump Model)

Describes the automatic defrost mode and its operation.

Protection Features

Details 3-minute protection, fan rotation, and high pressure switch operation.

Re-installation Guidelines

Re-installation Location Dangers

Warns against installing near flammable gases or in unsuitable locations.

Re-installation Location Requirements

Specifies requirements for installation space, level mounting, and drainage.

Places to Avoid for Re-installation

Lists locations unsuitable for re-installation to prevent malfunction or hazards.

Noise and Vibration Considerations for Re-installation

Advice on avoiding noise/vibration issues with neighbours and ensuring stable installation.

Troubleshooting Symptoms and Causes

Symptoms Not Indicating Failure

Common symptoms like misty air, noises, and smells that are not actual failures.

Symptoms Requiring Re-check

Checks for timer status, power, protective devices, and air settings.

Symptoms Requiring Immediate Action

Lists symptoms that require stopping operation and contacting the dealer.

Confirmation and Check Procedures

Check Code Display

Explains how error codes and indoor unit numbers appear on the remote display.

Confirmation of Error History

Procedure to check stored error history on the remote controller.