FILE NO. A12-006
SERVICE MANUAL
AIR-CONDITIONER
MULTI TYPE
PRINTED IN JAPAN, Nov., 2012 ToMo
This service manual provides relevant explanations about new outdoor unit (SHRM-i).
Please refer to the following service manuals for each indoor units.
< SUPER HEAT RECOVERY MULTI -i >
Outdoor Unit
Model name:
MMY-MAP0804FT8(Z)(ZG)-E MMY-MAP0804FT8(Z)(ZG)-TR
MMY-MAP1004FT8(Z)(ZG)-E MMY-MAP1004FT8(Z)(ZG)-TR
MMY-MAP1204FT8(Z)(ZG)-E MMY-MAP1204FT8(Z)(ZG)-TR
MMY-MAP1404FT8(Z)(ZG)-E MMY-MAP1404FT8(Z)(ZG)-TR
MMY-MAP0804FT8(Z)(ZG) MMY-MAP0804FT7(Z)(ZG)
MMY-MAP1004FT8(Z)(ZG) MMY-MAP1004FT7(Z)(ZG)
MMY-MAP1204FT8(Z)(ZG) MMY-MAP1204FT7(Z)(ZG)
MMY-MAP1404FT8(Z)(ZG) MMY-MAP1404FT7(Z)(ZG)
A08-004
A10-007
A12-005
A12-005
A10-022-2
SVM-05052-1
SVM-09-059
SVM-11-036
A10-033
<4-way Cassette Type > ( MMU-AP
∗∗∗∗
H )
<2-way Cassette Type > ( MMU-AP
∗∗∗∗
WH )
<Concealed Duct Standard Type> ( MMD-AP
∗∗∗∗
6BH-E )
<Slim Duct Type> ( MMD-AP2244SPH-E, AP274SPH-E )
<Air to Air Heat Exchanger with DX Coil Unit Type>
High-wall Compact Type ( MMK-AP
∗∗∗
4MH-E )(Made in Thailand model)
High-wall Type ( MMK-AP
∗∗∗
3H )(Made in Thailand model)
Console Type ( MML-AP
∗∗∗∗
NH-E )(Made in Thailand model)
Other indoor units ( MM
-AP
∗∗∗∗
H-E )
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk

Table of Contents

Questions and Answers:

Toshiba MMY-MAP1404FT8(Z)-TR Specifications

General IconGeneral
Power SourceElectric
RefrigerantR410A
Operating Temperature (Cooling)up to 46°C
TypeSplit System Air Conditioner
Power Supply380-415V

Summary

Super Heat Recovery Multi -i Section

Outdoor Unit Models

Lists the available outdoor unit models for the system.

New Refrigerant R410A Information

Wiring Diagrams Section

Outdoor Unit Wiring Diagrams

Wiring diagrams specific to the outdoor unit.

Indoor Unit Wiring Diagrams

Wiring diagrams for various types of indoor units.

Parts Rating Section

Outdoor Unit Parts Rating (50Hz)

Parts rating for outdoor units operating on 50Hz.

Outdoor Unit Parts Rating (60Hz)

Parts rating for outdoor units operating on 60Hz.

Outdoor Inverter Parts Rating (50Hz)

Parts rating for outdoor inverter units operating on 50Hz.

Outdoor Inverter Parts Rating (60Hz)

Parts rating for outdoor inverter units operating on 60Hz.

Outdoor Unit Parts Layout

Illustrates the layout of parts within the outdoor unit.

Inverter Assembly Parts Layout

Illustrates the layout of parts within the inverter assembly.

Outdoor Inverter Print Circuit Board Details

Details of the outdoor inverter print circuit board.

Refrigerant Piping Systematic Drawing

System Refrigerant Piping Schematic Diagrams

Schematic diagrams of the system's refrigerant piping for various modes.

Control Outline Section

Indoor Unit Control Outline

Control outline specifically for indoor units.

Outdoor Unit Control Outline

Control outline specifically for outdoor units.

Applied Control and Functions Section

Indoor Controller Block Diagram

Block diagram of the indoor controller.

Applied Control for Outdoor Unit

Details applied controls for outdoor units.

Applied Control Using Optional Outdoor Unit Boards

Functions available via optional P.C. boards for outdoor units.

Test Operation Procedures

Test Operation Procedure and Summary

Outlines the steps and summary for performing test operations.

Pre-Test Operation Checks (Electrical Wiring)

Checks to be performed before powering on for test operation.

Check Items After Main Power-on

Checks to be performed after the main power is turned on.

Address Setup Procedures

Procedures for setting addresses for units and systems.

Troubleshooting During Test Operation

Troubleshooting guide for issues encountered during test operation.

Test Operation Checks

Procedures for checking operations during test mode.

Service Support Functions

Functions available for service support.

Troubleshooting Section

Troubleshooting Overview

General overview of troubleshooting procedures and required tools.

Troubleshooting Method

Method for diagnosing faults based on check codes.

Troubleshooting Based on Remote Controller Display

Diagnosing faults based on information displayed on the remote controller.

Check Codes Displayed on Remote Controller and Outdoor Unit

Lists check codes displayed on remote controller and outdoor unit I/F board.

Backup Operation (Emergency Operation) Section

Outdoor Unit Refrigerant Recovery Method

Replacing Compressors Section

Outdoor Unit Parts Replacement Methods

P.C. BOARD EXCHANGE PROCEDURES

Outdoor Unit P.C. Boards

EXPLODED DIAGRAM/PARTS LIST

Refrigeration Circuit diagram

Indoor Unit

Outdoor Unit

Safety Precautions

Precautions for Safety

General safety precautions to be observed during installation, maintenance, and repair.

Specifications Section

Adding Refrigerant

New Refrigerant R410A

Safety Cautions for New Refrigerant

Safety precautions related to the new refrigerant.

Cautions on Installation and Service

Important cautions for installation and service work.