– 5 –
RAS-10YK-ES / RAS-10YA-ES
RAS-10YKX-T / RAS-10YAX-T
Specifications are subject to change without notice.
↑
↓
RAS-10YK-ES/10YA-ES RAS-10YKX-T/10YAX-T
MODEL
ITEM
Cooling
220V–240V 220V
Capacity kW
*
1
2,65–2,70 2,70
Phase Single
V220–240 220
Power source
Hz 50
Power consumption kW 0,80–0,85 0,80
Power factor % 96–94 96
V220V–240V 220V
Running current
Indoor/Outdoor A 0,15/3,65
Starting current A 16 11
Moisture removal lit/h 1,2
Indoor (H/M/L) dB (A) 44 / 36 / 29
Noise
(SPL at 1 meter)
Outdoor dB (A) (220–240V) 44 (220V) 46
Name of refrigerant R-410A R-22
Refrigerant
Rated volume kg 0,69 0,75
Refrigerant control Capillary tube
Gas side size mm 9,52
Connection type Flare connection
Liquid side size mm 6,35
Connection type Flare connection
Maximum length (of one way) m
*
210
Interconnection pipe
Maximum height difference
Indoor unit
Outdoor unit
m
5
Condensate drain pipe Outer diameter mm 16
INDOOR UNIT RAS-10YK-ES RAS-10YKX-T
Height mm 265
Width mm 790Dimensions
Depth mm 189
Net weight kg 8
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m³/h 650
Medium fan m³/h 510Air flow rate
Low fan m³/h 430
Fan motor output W 20
Air filter Polypropylene net filter (Washable)
OUTDOOR UNIT RAS-10YA-ES RAS-10YAX-T
Height mm 530
Width mm 770
Dimensions
Depth mm 200
Net weight kg 29 31
Condenser type Finned tube
Outdoor fan type Propeller
Air flow rate m³/h (220–240V) 1500 (220V)1700
Fan motor output W 18 (UE6-21SJ5P) 27 (UE6-31C5P) or 30 (HF-240-30A)
Model PA98X1T-4FZ RM5510GNE92
Compressor
Output W 750
Safety device Fuse, Overload relay
Auto louver Ye s
Usable outdoor temperature range °C21–43