66
FILE NO. SVM-03004(1)
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove packed valve cover and Electric
parts cover.
(3-Screws 4 x 10L)
3) Remove the cord clamp (2-Screws 4 x 22L)
and disconnect the connecting cable.
4) Remove the upper cabinet (4-Screws 4 x 10L)
Pulling out upword.
5) Remove the front cabinet.
(3-Screws 4 x 10L)
Pull the front right portion toward you, and
remove it pulling out upward.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw 4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw 4 x 10L)
3) Disconnect the lead wires.
10-2. Outdoor Unit
1 Common
procedure
2 Capacitor for
compressor
3 Capacitor for
fan motor
No. Part name Procedures Remarks
Cord clamp
3-Screws 4 x 10L
2-Screws 4 x 22L
Electric
parts cover
Packed valve cover
Upper
cabinet
Front
cabinet
Capacitor
for
compressor
Screws
4 x 10L
Capacitor band
Capacitor for fan motor
Screws
4 x 10L

Table of Contents