4-5. Indoor Unit (RAS-13NKD-E, RAS-10NKD-E, RAS-07NKD-E)
4-6. Outdoor Unit (RAS-13UA-E3)
No. Parts name Type Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 − 240 V, 50Hz
1 Compressor
PH225X2C-4FT
Winding resistance (Ω)C-RC-S
(at 20 C) 2.35 3.33
Output (Rated) 30 W, 6 poles, 1 phase, 220 − 240 V, 50Hz
2 Fan motor (for outdoor) HF-240-30B Winding resistance (Ω) Red-Black White-Black
(at 20 C) 245 388
3
Running capacitor
DS451155CBPQC AC 450 V, 1.5μF
°
°
4
Running capacitor
DS371356CPNB AC 370 V, 35 F
(for compressor)
μ
FILE NO. SVM-04022
− 16 −
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF-220-20-4A-1 AC Motor with 150°C thermo fuse
2 Thermo sensor (TA-sensor) ——— 10kΩ at 25°C
3 Switching transformer SWT-77
4 Microcontroller unit (IC30) TMP87CM40AN
5 Heat exchanger sensor
——— 10kΩ at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB01) D3SBA60 4A, 600 V
8 Capacitor (C03) KHM400VSSN47M225 47μF, 400 V
9 Fuse (F01) BET6.3A T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K320 560 V
11 Louver motor MP24Z 12VDC
12 Relay (Comp., RY01) DI1U Rating 25A/AC250 V, 12VDC